Operating Instructions
Transponder-Coded Safety Switch CET.-AS-…
12
(Translation of the original operating instructions) 2113689-04-07/19
7.2.
Emergency release (can be retrofitted)
Permits opening of a locked guard from outside the danger zone without tools. For mounting, see the mounting supplement.
Important!
Ì
It must be possible to operate the emergency release manually from outside the protected area
without tools.
Ì
The emergency release must possess a marking indicating that it may be used only in an emergen-
cy.
Ì
The actuator must not be under tensile stress during manual release.
Ì
The emergency release must be sealed or the misuse of the release function must be prevented in
the control system.
Ì
The release function meets all other requirements from EN ISO 14119.
Ì
The emergency release meets the requirements of Category B according to
EN ISO 13849-1:2008.
Ì
Loss of the release function due to mounting errors or damage during mounting.
Ì
Check the release function every time after mounting.
Ì
Please observe the notes on any enclosed data sheets.
7.2.1. Actuating emergency release
Ì
Turn emergency release clockwise until it clicks into place.
¨
Guard locking is released.
To reset, press the snap-in bolt inward using a small screwdriver or similar tool and turn
the emergency release back.
The zero sequence is sent via the ASi bus when the emergency release is actuated.
Open the guard and close it again after resetting the emergency release. The device will
then operate normally again.
7.3.
Escape release (optional)
Permits opening of a locked guard from the danger zone without tools (see chapter
Dimension drawing for safety switch CET.‑AS‑… on page 25
Important!
Ì
It must be possible to actuate the escape release manually from in-
side the protected area without tools.
Ì
It must not be possible to reach the escape release from the outside.
Ì
The actuator must not be under tensile stress during manual release.
Ì
The escape release meets the requirements of Category B according
to EN ISO 13849-1:2008.
7.3.1. Actuating escape release
Ì
Press the red release knob to the stop.
¨
Guard locking is released.
Pull the knob out again to reset.
The half-sequence/zero sequence is sent via the ASi bus when the escape release is actuated.
Open the guard and close it again after resetting the escape release. The device will then operate normally again.
25
30,4
71
Snap-in bolt