background image

Installation, Operation and Maintenance

V SERIES

Wallmount Air Conditioners

R410A Series

REV. 9/23/13

 

678629-V-C

 

Summary of Contents for V SERIES

Page 1: ...Installation Operation and Maintenance V SERIES Wallmount Air Conditioners R410A Series REV 9 23 13 678629 V C ...

Page 2: ...ted behind the center front access panel TO CHANGE SYSTEM FILTER A Turn the power to the unit off at the unit disconnect The disconnect is located on the front of the V Series unit behind a small access door B Remove the front center access door from the unit C Remove and replace the filters with the type and size indicated in the table below D Replace the access door and turn on the power to the ...

Page 3: ...pport the weight of the unit 9 Do NOT locate where heat lint or exhaust fumes will be discharged on the unit as from dryer vents 1 The V Series model units have top rain flashing built onto the unit The bottom mounting flange for all models is shipped separately and in place Refer to Section J Unit Installation for the recommended use of the bottom flange 2 Electrical entrances are located on the ...

Page 4: ...ECTRICAL HOOK UP STAGING OF ELECTRIC HEAT All V Series units with electric heat assemblies above 10 kW may be wired for single or two stage heat These models come factory wired for single stage operation For two stage operation remove the jumper bar from between the W2 and E terminal Wire the first stage heat to terminal W2 Wire the second stage heat to terminal E V SERIES UNITS ARE FOR USE IN SIN...

Page 5: ...5 EXPLODED PARTS DRAWING 18 24 30 36 ...

Page 6: ...EXPLODED PARTS DRAWING 48 60 6 ...

Page 7: ...SEMBLY LEFT SIDE PANEL V48 60 X X X X X X 10 2021 5012 ASSEMBLY REAR PANEL V18 24 X X 10 2022 5012 ASSEMBLY REAR PANEL V30 36 X X X X X 10 2023 5012 ASSEMBLY REAR PANEL V48 60 X X X X X X 11 2021 5003 ASSEMBLY DIVIDER DECK V18 24 X X 11 2022 5003 ASSEMBLY DIVIDER DECK V30 36 X X X X X 11 2023 5003 ASSEMBLY DIVIDER DECK V48 60 X X X X X X 12 2021 5005 ASSEMBLY BLOWER PAN V18 24 X X 12 2022 5005 ASS...

Page 8: ...3 POLE 3P 60 AMP X X X X 451955 DISCONNECT KIT 460V X X X 451956 DISCONNECT KNOB 460V X X X 0415 0028 LOW VOLTAGE TERMINAL BOARD X X X X X X X X X X X X X 451049 JUMPER BAR ASSEMBLY 451840 OPTION BOARD 454388 LOW PRESSURE SWITCH 451988 HIGH PRESSURE SWITCH 451992 FAN CYCLE SWITCH Part Numbers are Subject to Change OPTIONAL OPTIONAL ELECTRICAL COMPONENTS PARTS LIST OPTIONAL OPTIONAL OPTIONAL PART N...

Page 9: ... 4 2 10 10 10 8 6 29 55 52 52 30 60 60 60 10 6 6 6 10 10 10 10 V448B00A3 6 11 15 18 208 230 3 1 1 1 1 1 24 24 36 48 57 30 30 60 60 60 12 12 8 8 6 12 12 10 10 10 V448B00A4 6 11 15 460 3 1 1 1 1 12 12 19 25 15 15 30 30 14 14 14 10 14 14 14 10 V460B00A1 5 10 15 20 208 230 1 1 1 1 1 OR 2 1 OR 2 44 44 57 83 109 60 60 60 90 125 8 8 6 4 2 10 10 10 8 6 31 57 52 52 60 60 60 60 10 6 6 6 10 10 10 10 V460B00A...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...I J K L M N P Q R S T U V W X Y Z 18 24 36 34 185 8 281 16 12 201 2 8 17 8 20 289 16 11 8 711 2 21 2 101 2 181 2 261 2 347 8 11 8 16 32 115 16 29 16 291 2 271 8 275 8 30 36 40 38 185 8 281 2 14 18 8 17 8 28 289 16 11 8 711 2 21 2 101 2 181 2 261 2 39 11 4 181 4 363 8 2 29 16 291 2 27 1 8 315 8 48 60 431 8 41 24 271 2 16 30 10 21 4 30 361 2 11 8 87 21 2 101 2 181 2 261 2 42 11 8 193 4 391 2 61 2 33...

Page 14: ...14 ...

Page 15: ...14 NOTES 15 ...

Page 16: ...ount products Illustrations part numbers and others cover the general appearance of the units at the time of publication and the manufacturer reserves the right to make changes in design and construction at any time without notice For replacement parts contact National Coil Company 1998 FM 2011 Longview TX 75603 Phone 903 643 2261 Fax 903 643 2222 ...

Reviews: