www.ets-lindgren.com
Specifications
15
3.0 Specifications
Electrical Specifications
M
ODEL
6502
Frequency Range:
9 kHz—30 MHz
Dynamic Range:
85 dB at 10 kHz
125 dB at 1 MHz
Sensitivity (Typical):
-1 dB (uA/m) at 10 kHz
-42 dB (uA/m) at 1 MHz
1 dB Compression Point:
5 V/m
Power Required:
Battery-operated
Impedance (Nominal):
50 Ω
Connector:
BNC female
M
ODEL
6507
Frequency Range:
1 kHz—30 MHz
Dynamic Range:
76 dB at 10 kHz
116 dB at 1 MHz
Sensitivity (Typical):
11 dB (mA/m) at 10 kHz
-29 dB (mA/m) at 1 MHz
1 dB Compression Point:
10 V/m
Power Required:
13.8 VDC
Impedance (Nominal):
50 Ω
Connector:
BNC female
Summary of Contents for 6502
Page 1: ...6500 Series Loop Antennas User Manual ...
Page 6: ...vi www ets lindgren com This page intentionally left blank ...
Page 12: ...12 Introduction www ets lindgren com This page intentionally left blank ...
Page 18: ...18 Specifications www ets lindgren com This page intentionally left blank ...
Page 22: ...22 Mounting Instructions www ets lindgren com This page intentionally left blank ...
Page 26: ...26 Operation www ets lindgren com This page intentionally left blank ...
Page 27: ...www ets lindgren com Typical Data 27 6 0 Typical Data Model 6502 ...
Page 28: ...28 Typical Data www ets lindgren com Model 6507 ...
Page 29: ...www ets lindgren com Typical Data 29 Model 6509 ...
Page 30: ...30 Typical Data www ets lindgren com Model 6511 ...
Page 31: ...www ets lindgren com Typical Data 31 Model 6512 ...
Page 32: ...32 Typical Data www ets lindgren com This page intentionally left blank ...
Page 36: ...36 Warranty www ets lindgren com This page intentionally left blank ...
Page 39: ...www ets lindgren com 6505 Shielding Effectiveness Test Kit 39 ...
Page 44: ...44 EC Declaration of Conformity www ets lindgren com Model 6507 ...