Device Description
The ETROG
®
Care Platform is a wireless physiological monitoring system. The Platform
was developed with an Application Programming Interface intended to allow
development of user interface applications enabling health care professionals to access
collected vital information. The platform consists of:
•
Wearable Biosensor – MULTIVS ES008A
•
Adhesive patch
•
Chest Belt
•
Gateway Software
•
Server Software
MULTIVS ES008A is an integrated Bio-Sensors and wireless transceiver, rechargeable
battery-operated device that can be worn on the body torso via adhesive patch or chest
belt, Enabling recording of heart rate, electrocardiography (ECG), Photoplethysmogram
(PPG), Pulse Wave Transit time (PWTT), Changes in Blood Pressure, heart rate
variability(HRV) , R-R interval, respiratory rate, skin temperature, activity (including step
count) and posture (body position relative to gravity).
MULTIVS ES008A operates at spot or continues measurements mode to gather
physiological data from the person being monitored and transmit the data via encrypted
bi-directional communication to the gateway (smart phone / mobile device) when in
range of the Gateway that in turn will transmit the data to the server platform storage for
real-time monitoring and or future analysis.
Collected data by MULTIVS ES008A device is transmitted to the gateway immediately.
A continuous connection is needed between the sensor device and the gateway in order
to facilitate continuous data transmission. The wireless transmission of the data occurs
continuously with a delay or latency of 100 millisecond between continuous data
collection and transmission. Gateway data will be uploaded immediately after receiving
full measurement data to secure platform server. Authorized healthcare professionals
can configure the system parameters via the secure server platform to generate
notifications and alerts based on changes in measured data. The secure server platform
will trigger a notification when configured physiologic data parameters are exceeded.
In the event that MULTIVS ES008A device is NOT in range to communicate with
gateway, the measurement data will be stored in local device memory and will be
transmitted when communication is reestablished.
The gateway will pair automatically with device once in range.
The MULTIVS ES008A can operate as standalone device and collect measurement
data per pre-scheduled program, this data will be sent to gateway once it comes into
range – automatically.
In addition, the healthcare professionals can configure the type, mode (spot or
continues), Duration and Interval of measurements done by the sensor device.