Chapter 2 Installations
P/I-P5SVLL User`s Manual
15
JP4~ 5: On-Board LAN Enable/Disable selection
On-Board Fast Ethernet LAN chips can be disabled by shorting the JP8
or/and JP9 jumper.
Port #
Enable
Disable
PORT 1
JP4
JP4
PORT 2
JP5
JP5
JP6: LCD PANEL Power Selection
JP7 can be used to select the Panel LCD supple power: +3.3V or +5V.
The default setting is on +3.3V.User need to check the LCD panel spec
and adjust this jumper and make Panel work in specified power rail.
+3.3V
+5V
JP7: Panel Brightness Selection
OFF: Min Brightness.
ON: Max Brightness (Default).
OFF
ON