background image

 

16

 

Model No. 

EC 300.2A 

EC 500.4S 

ED 1200.1D 

 Ausgangsleitstung (RMS)  

 Stereo 1 Ohm  

 

N/A 

 

N/A 

 

1135W x 1 

  Stereo 2 Ohm   

225W x2 

230W x2 

730W x1 

  Stereo 4 Ohm  

130W x 2 

75W x2 + 145W x2 

410W x1 

Gebrückt (bridged) 

Power @ 2

Ω

 / channel  

 

N/A 

2300W x 1 strapped 

Power @ 4

Ω

 / channel  

455W x 1 

235W x + 440W x1 

N/A 

Maximale Strohmaufnahme 

52A 71A  101A 

Signal Rauschabstand 

>

70 dB (@1WCEA 2006 standard) 

THD  

<

0,02 % 

<

 0,5% 

Dämpfungsfaktor   

>

 200 

>

 100 

Kanalabstand  

>

 50 dB 

Frequenzgang (+/- 1.0 dB) 

10 Hz to 30 KHz 

10 Hz to 250 Hz 

Eingangsempfindlichkeit  

150mV to 5V 

Schutzschaltung  

ATO 2 x 30A 

ATO 2 x 40A 

ATO 3x 30A 

Eingang Stecker  

1 Paar RCA  

 Impedanz 

>

 10K

Ω

 

LED Display  

Grünes  LED Turn-on für Power und Turn-off für Protection display  

RCA Input / Output  

2 RCA input / 2 RCA output

4RCA input / 2RCA output 

2RCA input / 2 RCA output  

Level control  

1 Kontrolle mit  5V to 100mV variabel für 2 Kanäle  

Umschalter für  HPF / Flat /LPF 

1 Schalter für 2 Kanäle  

2 Schalter für 4 Kanäle  

N/A  

Variable Freq. Kontrolle: 

HPF /LPF

 

1 Kontrolle für  2 Kanäle 

2 Kontrollen für 4 Kanäle  

nur LPF  

 Frequenzgang  

Schaltbar 50 to 500 Hz oder 500 Hz to 5KHz 

50 to 250 nur LPF 

  Flankensteilheit  

12 dB / oct 

7.0 Subsonic Filter: 

Frequenzgang  

 

N/A  

N/A 

15 to 40 Hz variable  

Flankensteilheit  

N/A  

N/A  

12 dB /oct. 

 

Staggered Power (Model 500.4) 

– Zwei getrennt arbeitende Netzteile mit ebenfalls getrennten Ausgangsstufen für die Front- und Rear-Kanäle 

erzeugen entsprechende Ausgangsleistungen, dort wo sie benötigt werden. Modell EC 500.4 sind effektiv zwei Verstärker in einem Gehäuse. 

 

Staggered Power (Model 1200.1D) 

– kann durch den Parallelbetrieb Master-Slave wie beschrieben erzeugt werden. Die Leistungen erhöhen 

sich dadurch auf  
bei 4

Ω

 auf: 1400W x 1                bei 2

Ω

 auf: 2300W x 1

 

                                                                                       Techn. Daten können sich ohne vorherige Bekanntgabe ändern. 

 

 

 

 

F

EHLERBESEITIGUNG

 

 

Symptom

 

Diagnose

 

Maßnahme

 

Verstärker lässt sich nicht einschalten

 

Spannung von B+ oder Fernbedienung liegt nicht 
zwischen 10,5 und 15,5 V oder ist nicht vorhanden

Lichtmaschine, Batterie, Sicherung und Verkabelung 
überprüfen und ggfs. reparieren

 

Verstärkergeräusch

 

Verstärker hat keine ordnungsgemäße 
Masseverbindung

Verkabelung überprüfen und ggfs. reparieren

 

Knallgeräusch beim Einschalten 

 

Spannungsspitzen vom Steuergerät über die 
Signaleingänge

 

Relais Einschaltmodus zusätzlich einbauen

 

Motorengeräusch

 

Störgeräusche über die Signaleingangskabel 

 

Die Signalkabel im Abstand zu 
spannungsführenden Kabeln verlegen

 

Summary of Contents for EC 1200.1D

Page 1: ......

Page 2: ...EC 1200 1D 6 Remote Control Strapping Amplifiers for EC 1200 1D 7 Specifications 8 Troubleshooting 8 PRACTICE SAFE SOUND Continuous exposure to sound pressure levels over 100dB may cause permanent hearing loss High powered auto sound systems may produce sound pressure levels well over 130dB Use common sense and practice safe sound SAFETY INSTRUCTIONS This symbol with WARNING is intended to alert t...

Page 3: ...larity and do not Ground any speaker wires Do not connect any speaker wires together J Pass Thru Outputs The Pass Thru provides a convenient source for daisy chaining an additional amplifier without running an extra set of RCA cables from the front of the vehicle to the rear amplifier location K Subsonic Control EC 1200 1D Only A variable 15 40Hz high pass filter designed to prevent frequencies be...

Page 4: ...ful not to cut or drill into gas tanks fuel lines brake or hydraulic lines vacuum lines or electrical wiring when working on any vehicle 7 Never run wires underneath the vehicle Running the wires inside the vehicle provides the best protection 8 Avoid running wires over or through sharp edges Use rubber or plastic grommets to protect any wires routed through metal especially the firewall 9 ALWAYS ...

Page 5: ...pare the grounding cable for attachment to the amplifier by stripping 1 2 of insulation from the end of the wire Insert the bared wire into the GND terminal and tighten the set screw to secure the cable in place Prepare the chassis ground by scraping any paint from the metal surface and thoroughly clean the area Strip the other end of the wire and attach a ring connector Fasten the cable to the ch...

Page 6: ...5 INSTALLATION NOTE Mono amplifier speaker outputs A B are wired in parallel internally ...

Page 7: ... switch in the HPF position sets the amplifier to the high pass mode enabling frequencies above the cut off point to pass adjustable between 50 500Hz or 500 Hz 5KHz Placing the switch in the Flat position sets the amplifier to the all pass mode preventing any crossover adjustment allowing all frequencies to pass Placing the switch in the LPF position sets the amplifier to the low pass mode enablin...

Page 8: ...et the Master Slave switch out NOTE Only adjustments on the master amplifier will effective in functions 2 Connect RCA cables from the source signal to the input connection on the master amplifier 3 Set the Master Slave switch on the slave amplifier to the in position 4 Connect a RCA cable from the MAS OUT connector on the master amplifier to the SLV IN connector on the slave amplifier 5 Connect o...

Page 9: ... 50 to 250 LPF only Slope 12 dB oct Subsonic Filter Frequency Range N A N A 15 to 40 Hz variable Slope N A N A 12 dB oct Staggered Power Model EC 500 4S Two separate power supplies with two separate output sections for the front and rear channels In essence it is 2 completely separate amplifiers sharing the same chassis More power is created on the rear channels to allow the performance to be deli...

Page 10: ...atterie und Aufladung 12 Zusammenschalten von Verkabelung d Systems 13 Verstärker nur EC1200 1D 15 Fehlerbeseitigung 16 Technische Daten 16 HÖRSCHÄDEN Anhaltendes übermäßiges Ausgesetztsein von Lautstärken über 85dB kann das Hörvermögen auf Dauer beeinträchtigen ETON Verstärker sind imstande auch Lautstärken über 85dB zu produzieren ACHTUNG Bitte lesen Sie alle Warnungen in dieser Anleitung Diese ...

Page 11: ...0 250Hz LP Tiefpass Modus Nur bei Modellen EC 1200 1D H Externe Lautstärkeregler nur bei Modell EC 1200 1 D Zur Regelung der Ausgangsleistung Dämpft um bis zu 12 dB I Lautsprecheranschlüsse Die korrekte Polarität beachten und Lautsprecherkabel nicht erden J Signal Durchschleifung Der Signalausgang ist parallel zum Signaleingang geschaltet Sie können hier ohne Aufwand einen zweiten Verstärker ansch...

Page 12: ...abel 6 Beachten Sie bei der mechanischen Befestigung dass Sie keine Benzin oder Bremsleitungen beschädigen Befestigen Sie den Verstärker niemals am Benzintank Achten Sie auf ausrechenden Belüftung 7 Verlegen Sie die Kabel niemals außerhalb des Fahrzeugs 8 Legen Sie die Kabel nicht über scharfe Kanten Verwenden Sie Durchführungshüllen aus Gummi wenn Sie durch Metallteile verlegen müssen 9 Schützen ...

Page 13: ... Befestigungsschraube anziehen Achtung Das B Kabel MUSS mit einer Sicherung versehen sein Diese sollte nicht weiter als 45 cm vom Pluspol der Autobatterie entfernt sein Die Sicherungshalter im Motorraum müssen immer wasserfest sein 3 Verwenden Sie beim Anschluss immer geeignete Kabelschuhe 4 Isolieren Sie das Kabel für den Minuspol ca 13mm ab und schließen Sie dieses and die GND Buchse an Das Minu...

Page 14: ...13 EINBAU HINWEIS Monoverstärkerlautsprecherausgänge A u B sind parallel angeschlossen ...

Page 15: ...enzen oberhalb des Grenzpunkts durchgelassen kann zwischen 50 und 500 Hz bzw 500 5k Hz eingestellt werden Zur Wahl des All Pass Modus den Schalter am Verstärker in die FLAT Position bringen Dadurch wird eine Anpassung der Frequenzweiche verhindert und alle Frequenzen werden durchgelassen Zur Wahl des Low Pass Modus den Schalter am Verstärker in die LP Position bringen Dadurch werden Frequenzen unt...

Page 16: ... nicht für Impedanzlasten unter 2 Ω empfohlen 1 Entscheiden Sie welcher von den beiden Verstärkern der Master ist und den Master Slave Schalter in die Position Out bringen HINWEIS Nur die am Master Verstärker vorgenommenen Einstellungen wirken sich auf den Ausgang an den angeschlossenen Lautsprecher aus 2 Cinch Kabel des Steuergerätes an die Eingänge des Master Verstärkers anschließen 3 Den Master...

Page 17: ...50 nur LPF Flankensteilheit 12 dB oct 7 0 Subsonic Filter Frequenzgang N A N A 15 to 40 Hz variable Flankensteilheit N A N A 12 dB oct Staggered Power Model 500 4 Zwei getrennt arbeitende Netzteile mit ebenfalls getrennten Ausgangsstufen für die Front und Rear Kanäle erzeugen entsprechende Ausgangsleistungen dort wo sie benötigt werden Modell EC 500 4 sind effektiv zwei Verstärker in einem Gehäuse...

Reviews: