MOVEMENT AND INSTALLATION
²
When moving the freezer, the angel between the cabinet and the ground should not be less than 45
o
in order to protect
the compressor and refrigerating system.
²
Position the freezer in a dry and well-ventilated place. Keep the freezer away from direct sunlight, heaters, and corrosive
gases.
²
The normal operation of the freezer depends on the heat radiation of the condenser. For the initial use, the packing foam
must be taken off and at least 150mm space must be left around the freezer.
TROUBLESHOOTING
Problem
Cause
Remedy
The compressor runs for 1-5
minutes and stops
The voltage is not within the normal range
Switch off power and restart when
power is normal
The refrigerant has leaked
The compressor runs, but
inner liner does not get cold
The system is blocked
Contact your local dealer
The ice layer on the evaporator is too thick
Defrost
The door is being opened and closed too frequently
The door should be opened as little
as possible
The inner liner is very cold,
and the compressor runs
continuously.
The condenser is not well-ventilated. The controller
is faulty
Select a well-ventilated place
“+” and “-” are switched
Rectify
The controller is faulty (the power indicator is not
on)
Contact your local dealer
The compressor does not run
The thermostat is set too high; the ambient
temperature is too low
Use as a freezer
The freezer is not placed properly
Make the freezer level
Some parts come loose
Contact your local dealer
The freezer is noisy
The pipes are touching
Contact your local dealer
Warranty:
•
If this product has not been operated according to this user manual, the warranty does not cover.
•
If this product has been dropped or been exposed to mechanical stress, the warranty does not cover.
•
If this product has been opened, the warranty does not cover.
•
If there have been mechanical or electrical changes on this product, the warranty does not cover.
•
You have 24 months warranty on this product according to local law.
Service User Information:
If you want to operate this unit at 12VDC, use Etomer
TM
Power Inverter ET-500PS which is
approved to operate this REFRIGERATOR-FREEZER (ET-AC40E) at 12VDC.
Use of other types of power inverter may damage the unit and the warranty does NOT cover.
Use only ET-500PS if you want to operate the unit at 12VDC.