MOVEMENT AND INSTALLATION 

²

 

When moving the freezer, the angel between the cabinet and the ground should not be less than 45

in order to protect 

the compressor and refrigerating system.  

²

 

Position the freezer in a dry and well-ventilated place. Keep the freezer away from direct sunlight, heaters, and corrosive 
gases. 

²

 

The normal operation of the freezer depends on the heat radiation of the condenser. For the initial use, the packing foam 
must be taken off and at least 150mm space must be left around the freezer. 

 

TROUBLESHOOTING 

Problem 

Cause  

Remedy 

The compressor runs for 1-5 
minutes and stops 

The voltage is not within the normal range 

Switch off power and restart when 
power is normal 

The refrigerant has leaked 

The compressor runs, but 
inner liner does not get cold 

The system is blocked 

 
Contact your local dealer 

The ice layer on the evaporator is too thick 

Defrost  

The door is being opened and closed too frequently 

The door should be opened as little 
as possible 

 
 
The inner liner is very cold, 
and the compressor runs 
continuously. 

The condenser is not well-ventilated. The controller 
is faulty 

Select a well-ventilated place 

“+” and “-” are switched 

Rectify  

The controller is faulty (the power indicator is not 
on) 

Contact your local dealer 

 
 
The compressor does not run 

The thermostat is set too high; the ambient 
temperature is too low 

 
Use as a freezer 

The freezer is not placed properly 

Make the freezer level 

Some parts come loose 

Contact your local dealer 

 
The freezer is noisy 

The pipes are touching 

Contact your local dealer 

 
Warranty: 

 

If this product has not been operated according to this user manual, the warranty does not cover.  

 

If this product has been dropped or been exposed to mechanical stress, the warranty does not cover.  

 

If this product has been opened, the warranty does not cover.  

 

If there have been mechanical or electrical changes on this product, the warranty does not cover.  

 

You have 24 months warranty on this product according to local law. 

 

Service User Information: 

If you want to operate this unit at 12VDC, use Etomer

TM

 Power Inverter ET-500PS which is  

approved to operate this REFRIGERATOR-FREEZER (ET-AC40E) at 12VDC.  
Use of other types of power inverter may damage the unit and the warranty does NOT cover.  
Use only ET-500PS if you want to operate the unit at 12VDC.  

 

 
 
 
 

Etomer

TM 

Viborggade 9, 
DK-2100 Copehagen OE 
Denmark 
 

 

Email:salg@etomer,dk   

 

www.etomer.dk

   

 

 

Phone: +45 3543 9798 

 

 