EN 22
INSTALLATION
Ventilation
The electronics in the appliance need cooling. The appliance will
automatically switch off if there is insufficient air circulation. There
are ventilation openings on the underside of the appliance. It must be
possible for cool air to be drawn in through these openings. There are
outlet openings on the underside and at the front of the appliance.
Constructing above a load or an oven or fixed pannel
Ventilation occurs through the plinth (A) and the back of the cupboard
(B). Saw out the ventilation openings (min. 100 cm
2
). Air supply A is not
necessary if there is another opening that can supply air together with
opening B.
Make sure the crossbar does not impede the airflow. Plane or saw the
crossbar C diagonally if necessary.
Do not allow a drawer to block the ventilation openings on the bottom
of the appliance. If there is a drawer under the hob, a gap of at least the
width of the hob should be made at the front. The distance between the
drawer A and the hob should be at least 10 mm.
A
C