General

This appliance should be connected to the power supply by a 
recognized fitter who is familiar with, and works according to the 
correct safety regulations. This appliance meets the European 
requirements.

Important that you know:

•  The minimum distance between the supporting surface for the 

cooking vessels on the gashob and the lowest part of the range 
hood must be not less than 65 cm. For use with an electric, ceramic 
or induction hob, this distance must be at least 55 cm.

•  If the cooker hood is to be fitted to an existing duct no other 

appliances, such as a geyser or heater, may be connected to that 
same duct.

•  Consider local regulations with respect to the ventilation of gas 

appliances.

•  The shorter the duct, and the fewer the bends in it, the better the 

cooker hood will work.

•  Before you start drilling check that there are no installation cables 

present.

•  The connecting pipe for the cooker hood has a diameter of  

150 mm. It is best also to use a flue pipe of the same diameter.

•  The installation material supplied with this range hood is designed 

for fixing to reinforced concrete or masonry walls. For some types 
of walls you may need special plugs and screws.

Summary of Contents for A4345TRVS

Page 1: ...GEBRUIKSAANWIJZING MODE D EMPLOI BEDIENUNGSANLEITUNG INSTRUCTIONS FOR USE AFZUIGKAP HOTTE CHEMIN E DUNSTABZUGSHAUBE COOKER HOOD A4345TRVS AV760RVS AV790RVS...

Page 2: ...ilisation FR 3 FR 12 DE Anleitung DE 3 DE 12 EN Manual EN 3 EN 12 Gebruikte pictogrammen Pictogrammes utilis s Benutzte Piktogramme Pictograms used Belangrijk om te weten Important savoir Wissenswerte...

Page 3: ...nleiding 4 Gebruik Bediening 5 Onderhoud Reinigen 6 Vetfilters verwijderen 7 Het koolstoffilter vervangen 7 Verlichting 8 Installatie Algemeen 9 Elektrische aansluiting 10 Montage van de schouwkap 11...

Page 4: ...t u snel op de hoogte van alle mogelijk heden die dit toestel u biedt U vindt informatie voor uw veiligheid en over het onderhoud van het toestel Bewaar de gebruiksaanwijzing en het installatievoorsch...

Page 5: ...n 1 2 of 3 De afzuigkap schakelt in op de corresponderende stand 2 Zet de schuifregelaar B naar stand 0 De ventilator schakelt uit Verlichting in en uitschakelen 1 Zet de schuifregelaar A op stand 1 D...

Page 6: ...igheidsvoorschriften Afzuigkap Maak de afzuigkap schoon met een sopje en een zachte doek Daarna met schoon water nabehandelen Gebruik geen agressieve schoonmaakmiddelen zoals bijvoorbeeld soda Het lak...

Page 7: ...gkap niet is aangesloten op een afvoerkanaal 1 Verwijder de vetfilters 2 Bevestig de koolstoffilters aan de motor 3 Plaats de vetfilters Belangrijk De verzadiging van het filter is afhankelijk van de...

Page 8: ...W Fitting Voltage V Afmeting mm ILCOS Code 40 120 120 10 10 G E H P L 340 599 205 100 400 120 16 270 522 365 502 M 3 E14 220 240 102 x 35 DRBB C 3 220 240 E14 35 102 Modellen AV760RVS en AV790RVS De v...

Page 9: ...estaand afvoerkanaal mogen geen andere apparaten op dat kanaal aangesloten zijn zoals een geiser of kachel Neem de plaatselijk geldende voorschriften in acht met betrekking tot de beluchting van gasap...

Page 10: ...installatie De aansluiting op het elektriciteitsnet moet als volgt uitgevoerd worden BRUIN L fase BLAUW N nul Deze afzuigkap is voorzien van een aansluitstekker Installeer de afzuigkap zodanig dat de...

Page 11: ...draagvlak voor de afvoer van de afzuigkap Bevestig de kap met behulp van de schroeven aan het draagvlak Sluit de afvoerpijp aan op de motorflens Sluitprofiel De ruimte tussen de rand van de kap en de...

Page 12: ...te vuilnisbak aangebracht Dit betekent dat het apparaat aan het einde van zijn levensduur niet bij het gewone huisvuil mag worden gevoegd Het toestel moet naar een speciaal centrum voor gescheiden afv...

Page 13: ...n 4 Utilisation Commande 5 Entretien Nettoyage 6 Elimination des filtres 7 Remplacement des filtres charbon 7 clairage 8 Installation G n ralit s 9 Connexion lectrique 10 Montage de la hotte chemin e...

Page 14: ...e toutes les fonctions de l appareil Il contient des informations relatives aux consignes de s curit et l entretien de l appareil Conservez ce mode d emploi et le guide d installation Ils peuvent tre...

Page 15: ...souhait e 1 2 ou 3 La hotte aspirante est activ e en fonction de la position s lectionn e 2 Mettez le s lecteur de r glage B en position 0 Le ventilateur est d sactiv Marche et arr t de l clairage 1 M...

Page 16: ...ent mentionn es Hotte Vous pouvez nettoyer la hotte l eau savonneuse et une serviette douce puis rincer l eau claire Ne pas utiliser de produits d entretien abrasifs Frotter la peinture laqu e de votr...

Page 17: ...rd e aucun conduit Placez le filtre charbon 1 Enlevez les filtres graisse 2 Fixez les filtres charbon au moteur 3 Placez les filtres graisse Remarque Le charbon de bois activ sature apr s une utilisat...

Page 18: ...W Culot Voltage V Dimension mm Code ILCOS 40 120 120 10 10 G E H P L 340 599 205 100 400 120 16 270 522 365 502 M 3 E14 220 240 102 x 35 DRBB C 3 220 240 E14 35 102 Mod les AV760RVS et AV790RVS La ho...

Page 19: ...existant aucun autre appareil lectrom nager ne doit tre raccord au m me conduit exemples chauffe eau po le Ne pas oublier les r glements locaux en vigueur concernant l a ration des appareils gaz Un c...

Page 20: ...nnection avec le r seau lectrique doit tre x cut e comme suit BRUN Phase L BLEU Phase N Cette hotte aspirante est quip e d une fiche de raccordement Installez la hotte de mani re ce que la prise soit...

Page 21: ...ez une ouverture dans la surface portante pour le canal d vacuation de la hotte Fixez la hotte la surface portante avec les vis Raccordez le tuyau d vacuation la bride Profil de fermeture Il est poss...

Page 22: ...produit un symbole repr sentant un conteneur ordures barr d une croix Cela signifie qu l issue de sa dur e de vie l appareil ne peut tre mis au rebut avec les d chets m nagers classiques L appareil do...

Page 23: ...ung 4 Einleitung 4 Gebrauch Bedienung 5 Pflege Reinigen 6 Fettfilter entfernen 7 Austausch der Kohlefilter 7 Beleuchtung 8 Installation Allgemein 9 Elektroanschluss 10 Montage der Haube 11 Anlagen Ent...

Page 24: ...t aller M glichkeiten die das Ger t bietet Sie erhalten Informationen zur Sicherheit und zur Wartung des Ger ts Bewahren Sie diese Bedienungsanleitung und die Installationsanweisungen sorgf ltig auf S...

Page 25: ...shaube wird auf die entsprechende Stufe geschaltet 2 Stellen Sie den Schieberegler B auf die Stufe 0 Der Ventilator wird ausgeschaltet Beleuchtung ein und ausschalten 1 Stellen Sie den Schieberegler A...

Page 26: ...zur ckzuf hren sind Dunstabzugshaube Die Dunstabzugshaube k nnen Sie mit Seifenlauge und einem weichen Tuch reinigen danach mit klarem Wasser nachsp len Gebrauchen Sie keine agressiven Putzmittel wie...

Page 27: ...uss der Kohlefilter verwendet werden 1 Entfernen Sie die Fettfilter 2 Befestigen Sie die Kohlefilter am Motor 3 Setzen Sie die Fettfilter ein Achtung Nach mehr oder weniger langem Gebrauch ist die Akt...

Page 28: ...Ma e mm ILCOS Code 40 120 120 10 10 G E H P L 340 599 205 100 400 120 16 270 522 365 502 M 3 E14 220 240 102 x 35 DRBB C 3 220 240 E14 35 102 Modelle AV760RVS und AV790RVS Die Haube ist mit einem auf...

Page 29: ...Abluftkanal angeschlossen wird d rfen auf diesem keine anderen Ger te angeschlossen sein wie Gasdurchlauferhitzer und Gasofen Denken Sie an die rtlichen Vorschriften bez glich Entl ftung von Gasger te...

Page 30: ...romnetz ist folgendermassen durchzuf hren BRAUN Phase L BLAU Phase N Diese Dunstabzugshaube ist mit einem Stecker versehen Installieren Sie die Dunstabzugshaube so dass der Stecker erreichbar ist Brin...

Page 31: ...Ablagefl che f r das Abluftrohr der Abzugshaube Befestigen Sie die Abzugshaube mithilfe der Schrauben an der Ablagefl che Schlie en Sie das Abluftrohr an den Motorflansch an Abdeckprofil Der Bereich...

Page 32: ...ist gekennzeichnet Dies bedeutet das am Ende seiner Nutzzeit das Produkt nicht zusammen mit dem Siedlungsabfall beseitigt werden darf Es kann zu den eigens von den st dtischen Beh rden eingerichteten...

Page 33: ...troduction 4 Use Controls 5 Maintenance Cleaning 6 Removing the grease filters 7 Replacing the carbon filter 7 Lighting 8 Installation General 9 Electrical connection 10 Mounting the canopy hood 11 Ap...

Page 34: ...u a quick overview of all the possibilities offered by the appliance You will find information on safety measures and maintaining the appliance Please retain this user manual and the installation guid...

Page 35: ...with slide control B The extractor hood switches on in the corresponding position 2 Set the slide control B to 0 The fan will switch off Switching lighting on and off 1 Set the slide control A to 1 T...

Page 36: ...or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Cooker hood Clean the cooker hood with soapy water and a soft cloth Then wipe with clean...

Page 37: ...er hood is not ducted 1 Remove the grease filters 2 Attach the carbon filters to the motor 3 Replace the filter grids in the extractor hood Note Saturation of the activated charcoal will eventually oc...

Page 38: ...ilters Lamp Power W Socket Voltage V Dimension mm ILCOS Code 40 120 120 10 10 G E H P L 340 599 205 100 400 120 16 270 522 365 502 M 3 E14 220 240 102 x 35 DRBB C 3 220 240 E14 35 102 Models AV760RVS...

Page 39: ...55 cm If the cooker hood is to be fitted to an existing duct no other appliances such as a geyser or heater may be connected to that same duct Consider local regulations with respect to the ventilatio...

Page 40: ...nection to the mains is carried out as follows BROWN phase L BLUE phase N This canopy hood has been provided with a power plug When installing the hood make sure that this plug remains accessible We r...

Page 41: ...n opening in the surface for the cooker hood outlet Fit the hood to the surface using the screws Connect the exhaust air pipe to the motor flange Closing element The space between the edge of the hood...

Page 42: ...sing of electric household appliances is compulsory this appliance carries the symbol of a crossed out dustbin This means that at the end of its working life you may not dispose of the appliance as ho...

Page 43: ...EN 13...

Page 44: ...726657 VER 1 10 07 2018 726657 726657...

Reviews: