Installation manual (v. 2/2017)
Vehicle unit ETLOC-50 ONLINE
6
2.1 Input IGNITION (connection of this input is mandatory)
Input IGNITION is used to monitor a running engine of a vehicle.
When the
engine is running there must always be
a v12/24V on the input.
Input IGNITION
can be connected to any circuit
in the vehicle,
which is active only when
the engine is running
.
2.2 Input BUSINESS JOURNEY
Via the switch connected to this input the driver sets the type of journey (closed switch
indicates business journey, open switch indicates private journey).
Place the switch in an easily accessible and clear space from the driver's perspective
(e.g. a vehicle dashboard) in a pre-drilled hole. Connect the switch between vehicle frame
(GND) and purple wire.
In case the journey switch will
not be used in the vehicle
it is necessary, for permanent
identification of business journeys in the system, to
ground the purple wire
.
Grounding
of the purple wire must be done in the
shortest possible distance
from the
negative pole of the car battery.
2.3 Input 3
Input 3 is used as an independent information input, which monitors status or activities of a
particular device within the vehicle (e.g. alarm activation, switching of a cooling device, usage
of a beacon or warning lights, SOS button activation, working position of a plow, opening the
lid of a tank, opening of a cargo space etc.).
Orange wire
- input 3 is activated by a v12/24V. Voltage impulses shorter than 0.8
second are not being detected.
Note:
In an online monitoring system environment a user can define what reaction shall be executed
upon information input 3 activation.
There are two options, which can be combined:
a) send an "information SMS" to a predefined tel. numbers upon input 3 activation
b) in a logbook (on map background) mark part of route for which the input 3 was active
IMPORTANT