INSTALLATION
DOC_DEV_IPL_User guide_D
Page 25
IPL-X-260
5 positions screw terminal : RS422 isolated
Position
Signal
Function
1
Tx+
Emission po
2
Tx-
Emission polarity -
3
Com
Common isolated
4
Rx+
Reception po
5
Rx-
Reception polarity -
IPL-X-220 et IPL-X-230
RJ45 connector : RS232
To connect a DCE
Position
Signal
Direction
Function
RJ45
1
DTR - 108
OUT
Data terminal ready
2
TD - 103
OUT
Data Emission
3
RD - 104
IN
Data Reception
4
DSR - 107
IN
Data set ready
5
SG - 102
-
Ground
6
Not used
OUT
-
7
CTS - 106
IN
Clear to send
8
RTS - 105
OUT
Request to send
OUT = Signal supplied by the RAS.
IN = Signal supplied by the external device.
IPL-X-220 et IPL-X-230
RJ45 connector : RS232
To connect a DTE
Position
Signal
Direction
Function
RJ45
1
CD - 109
OUT
Carrier detect
2
RD - 104
OUT
Data Reception
3
TD - 103
IN
Data Emission
4
DTR - 108
IN
Data terminal ready
5
SG - 102
-
Ground
6
DSR - 107
OUT
Data set ready
7
RTS - 105
IN
Request to send
8
CTS - 106
OUT
Clear to send
OUT = Signal supplied by the RAS.
IN = Signal supplied by the external device.