South Bend, Indiana USA
|
networketi.com
ASM-1 INSTALLATION GUIDE | PART NO.
23681
REV
A
PACKING LIST
QTY.
PART NO. DESCRIPTION
1
23658
ASM–1 Smart Manifold, AC Power Supply
1
24303
Documentation CD ROM, ADH NETCOM and ASM–1 Smart Manifold
1
23681
ASM–1 Smart Manifold Installation Sheet (this document)
1
23678
ASM–1 Accessory Kit
2
18198
1/8" NPT to 1/4" Barbed Brass Fitting
2
23428
1/8" NPT to 3/8" Barbed Brass Fitting
4
23245
Mounting Bracket
1
17618
Power Cord
8
11040
Rack-mounting screw (#8-32)
8
10641
#8 Split Washer
CONNECTIONS
Ports are factory configured as: Port 1 – Input; Ports 3 and
4 – Outputs; Port 8 – Bleed Valve. Ports 2, 5, 6, and 7 are
factory configured as Unused. Settings may be changed,
but use these initially.
1. For the dehydrator, connect a 1/8” NPT to 3/8” fitting
to Input Port 1 using Teflon thread tape.
2. For the equipment lines, connect fittings as needed to
Output Ports 3 and 4 using Teflon thread tape. Refer to
Instruction Manual for more information.
3. Connect required data and alarm relay ports. RS-422
and RS-232 ports may require configuration changes
via the web interface. See Instruction Manual for
more information.
4. Connect AC power cord. System can be connected
to 100 VAC – 240 VAC power without requiring any
configuration change.
5. Configure Smart Manifold as described on this
Installation Sheet, then shut off Manifold power.
6. Configure system dehydrator(s) as needed. Turn Smart
Manifold power back on.
MODEL ASM-1
NETCOM
®