QUICK REFERENCE INSTALLATION GUIDE | PART NO.
25548
REV
0.0
2
RACK MOUNTING
The dehydrator is equipped with positions
for either flush-mounting (for dual-post racks
and enclosures) or center- mounting (for
single-post racks).
If using mounting rails (not supplied), do not
install mounting brackets.
WALL MOUNTING CONFIGURATION
To configure the dehydrator for wall mount
installation, remove the front panel and the
portion of the vented cover with the ETI logo.
Reinstall the front panel so that it will be in
the new front position once the dehydrator is
positioned for wall mounting. Reinstall the
small vented panel so that it will be in the
new bottom position.
WALL MOUNTING
Ensure the mounting surface and hardware
are suitable to support a static load of
approximately four times the weight of the
unit, or 64 pounds (29 kg). Use four
appropriate 5/16" mounting fasteners to
attach the unit and ensure stable mounting.
The dehydrator is equipped with four
brackets for wall mounting.
RESET
ETHERNET
ALARM
RELAYS
RS422 A /RS422 B
EQUIPMENT
GROUND
MODEL
S/N
VOLTS
AMPS
WATTS
HERTZ
PRESS
.
P/N
RANGE
ETI INC.
SOUTH BEND, INDIANA U.S.A
ADH NETCOM
2 0 -7 5 VDC
5 .0 A@ 2 0 VDC
1 0 0
DC
0 .1 -7 .5 psi
2 5 5 2 7
0 0 0 1
SUPPLY
SUPPLY
20-75 VDC
- +
2
1
- +
RS232