ETHINK KL6600 Manual Download Page 1

                                                                                      KL6600 

www.ethink-spa.com

                                                                  1 

The Manual of KL6600 

. Overview of the Panels

 

 

                                                      Fig. 1.The plan of panel 
 

AUX

 

                              Fig. 2.The installation plan of sever buttons

156*72mm

 

 

.The function summary 

1. Three working modes: Normal Mode, Economy Mode and Filter Mode. 

2. Plug-and-play mode is to get easy operation and easy installation.   
3. 24 hours clock display and setup of circulation-cleaning 
4. Max 3KW of the heater, water temperature display and the setting function. 
5. 1 surfing pump and 1 blower and an additional load AUX output 

6. 1 impact massage pump, divide into ordinary impact and strong impact. 
7. Synchronous changing or fixed color with multiple lights and ozone antivirus system. 

Summary of Contents for KL6600

Page 1: ...er Mode 2 Plug and play mode is to get easy operation and easy installation 3 24 hours clock display and setup of circulation cleaning 4 Max 3KW of the heater water temperature display and the setting...

Page 2: ...over voltage if it is beyond 260VAC then LED shows In these two kinds of situation the system will not go into normal operation Under this circumstance that the input voltage is normal the system woul...

Page 3: ...ton and hold until it appears some icons or enters to a certain status 4 Click pressing means to click the button and let go right now within a second Working Mode 1 When A1 ON there is without neithe...

Page 4: ...ice filtering antivirus cycle every day But it is only able to set the start time for the first filtering antivirus cycle And the second filtering cycle is automatically added it will starts after 12...

Page 5: ...7 7 If the current water temperature shows 98 but the real water temperature is 100 At the moment as long as to adjust the fine tuning number for 2 the showing temperature will turn into 100 1 2 3 4...

Page 6: ...sturizing function and at this time there is with 12 V power output of LED ON With moisturizing function B4 OFF Only with 1 surfing pump ON With 2 surfing pump note 1 The setting of all the jumpers is...

Page 7: ...r temperature is reaching 46 7 8 or above all the heaters and circulating pumps stop working The operation of auto moisturizing B3 ON 1 When the water level pin detects that there is no water LCD show...

Page 8: ...Installation structure KEY_DIS SENSOR A OZONE 220V 12VAC 1A 250V HT48R06A 1 LIGHT HT46R23 WCS2705 WCS2705 ON 1 2 3 4 5 6 7 8 ACN P1 P1L BLOWER ACN AUX ACN ACL ACN ACN ACN HT1 HT2 KL6600 ACN P1L Fig 8...

Page 9: ...ure that the water flow inside the heater is not enough 1 Check whether filter is blocking or is just replaced 2 Check whether the metering valves and circulating pump are normal or not 3 If the above...

Page 10: ...240V Compression strength 1250V 1 minute Not being punctured Insulation resistance 200M Waterproof level IPX5 Electric shock preventing 1 class 2 Maximum output load index Heater 4KW 220 240VAC Surfi...