EtherWAN EX78000 Series Installation Manual Download Page 2

 

 

 

 

Copyright 2017 EtherWAN Systems, Inc.

  

  Page 2 

 

All Rights Reserved 

EX78000  

8/15/2017 

W70G-EX780V2Q1

 

 
 

EX78000 Series Hardened Managed Ethernet Switch   

Installation Guide

 

Terminal Block 

The switch provides two power inputs on a 52-
57VDC terminal block. Only one power input is 
required to operate the switch. The terminal 
block has 5 terminal posts. 

  

 

Pin 

Description 

Power 1 

 

52-57VDC 

 

Power Ground 

Power 2 

 

52-57VDC 

 

Power Ground 

 

 

Earth Terminal 

Relay Output Rating 

0.5A @ 48VDC 

Relay Output Alarm 

The switch provides relay output contacts for 
signaling of a user-defined power or port failure. 
The relay output can be connected to an alarm 
signaling device. Current is 0.5A at 48VDC. 

 

 

Power-Up Sequence 

When you apply power: 

All 

Link/ACT

 LEDs blink momentarily. 

The 

Power 1 

LED goes ON.  

LEDs for every port connected to a device flash, 
as the switch conducts a Power On Self-Test. 

Console Configuration 

Connect to the switch console by connecting a 
DB-9 cable to the console port of the switch and 
to the serial port of a computer running a 
terminal emulation application (such as 
Hyperterminal or Putty).  
Configuration settings of the terminal-emulator: 
Baud rate: 115,200bps, Data bits: 8, Parity: none, 
Stop bit: 1, Flow control: none. 
The default login name is “root,” no password. 

Web Configuration 

Log in to the switch by launching a web browser 
and entering 192.168.1.10 in the address bar. 
Enter the default login ID: root (no password) 
and click “Login.” The system information screen 
will display as shown below. 

Other information 

DIN-Rail assembly, startup, and dismantling 

Assembly

:  Place  the  Switch  on  the  DIN  rail 

from  above  using  the  slot.  Push  the  front  of 

the  Switch  toward  the  mounting  surface  until 

it audibly snaps into place. 

Startup

: Connect the supply voltage to start 

the switch via the terminal block. 

 

Dismantling

: Pull out the lower edge and then 

remove the Switch from the DIN rail. 

 

 

 

Power wiring informati

on: 

Use cable type - AWG (American Wire Gauge) 18-
24 and the corresponding pin type cable 
terminals. Tighten terminal screws with a torque 
value of 1.7 lb-in. Do not use excessive force 
when fixing wiring. 
 

 The rating of the power wire used must 

be at least 105°C. 

 
If the equipment is used in a manner not 
specified by the manufacturer, the protection 
provided by the equipment may be impaired. 

 

The Ethernet switch should be mounted in an 
industrial control panel with ambient 
temperature not exceeding 75 degrees C. 
Manufacturer information: 

ETHERWAN SYSTEMS, INC.

 

4F-7, No. 79, Sec. 1, Xintai 5th Road, Xizhi 
District, New Taipei City 221, Taiwan 

 

 

3 Normal Open 

|

 2 Ground 

|

 1 Normal close 