Other Electrical and Safety Information 

(A) Elevated Operating Ambient - If installed in a closed or multi-unit rack 
assembly, the operating ambient temperature of the rack environment may 
be greater than room ambient. Therefore, consideration should be given to 
installing the equipment in an environment compatible with the maximum 
ambient temperature (Tma). 

B) Mechanical Loading - Mounting of the equipment in the rack should be 
such that a hazardous condition is not achieved due to uneven mechanical 
loading. 

C) Circuit Overloading - Consideration should be given to the connection of 
the equipment to the supply circuit and the effect that overloading of the 
circuits might have on overcurrent protection and supply wiring. Appropriate 
consideration of equipment nameplate ratings should be used when 
addressing this concern. 

D) Reliable Earthing - Reliable earthing of rack-mounted equipment should 
be maintained. Particular attention should be given to supply connections 
other than direct connections to the branch circuit (e.g. use of power strips). 

Do not disable the power cord grounding plug. The grounding plug is an 
important safety feature.  

Caution:  

This equipment shall be used with all power supplies connected 
simultaneously.  

This equipment is intended to be used in a restricted access location and by 
qualified personnel. This equipment is not suitable for use in locations where 
children are likely to be present. 

Les matériels sont destinés à être installés dans des EMPLACEMENTS À  
ACCÈS RESTREINT

 

 

 

 

 

 

 

 

 

 

This equipment must be connected to Protective earthing (PE) to AC mains 
ground. The protective earthing conductor shall be minimum 18 AWG and 
having green-and-yellow insulation. The thread diameter of screw type 
terminal shall be minimum 3.5mm.  

The ground wire should be installed first (earlier than live and neutral ires) 
and then removed. The grounding wire should be longer than live and neutral 
wires.  

When wiring the switch to power, unscrew the two retaining screws that hold 
the protective cover in place. The metal protective cover should be 
reattached after the wiring is completed to avoid the danger of electric 
shock.  

 

 

When stripping the cable sheath for connection to the terminal block, leave 
only 10mm of wires exposed for the connection. 

 

 

 

The power cord shall be IEC 60227 certified, rated 0.75 mm2 x 3C or UL 
recognized minimum 18AWG. 

 

 

 

 

 

 

 

 

 

 

 

Terminal Block: 

This product is intended to be supplied by certified DC power source and 
rated output rating: 48 VDC, 1 A minimum. 

 

 

 

 

 

AC Terminal Block 

AC power rating current is 0.6A.All power connection wiring by a qualified 
electrician in accordance with National Electrical Code, ANSI/NFPA 70 and 
Canadian Electrical Code, Part I, CSA C22.1. An IEC certified or UL listed 
single-phase type circuit-breaker, rated maximum 20A, shall be installed 
between mains circuit and equipment.  

Thumbscrews should be tightened with a tool after both initial installation 
subsequent access to the panel.  

 

Note:  

This equipment must use UL recognized Laser Class 1 optical transceiver. 

 

 

 

 

 

 

 

 

Hazardous voltages may occur within this unit when connected 

to all power supplies. Prevent access to hazardous voltages by 
disconnecting this equipment from all power supplies.  

Plug the power cord into a grounded (earthed) electrical outlet 

that is easily accessible at all times. 