EtherWAN ED3141 Quick Start Manual Download Page 2

10/100Base-TX Hardened Ethernet Extender 

 

2

The Port Status LEDs 

 

LEDs State Indication 

Steady Power 

on 

Power1 
Power2 
Power3

 

Off Power 

off 

Ethernet 

Steady  Valid network connection established 

Flashing 

Transmitting or receiving data 
ACT stands for ACTIVITY 

Link/ACT 

Off 

Neither valid network connection established nor
transmitting/receiving data 

Steady 

Connection in full-duplex mode 
FDX stands for FULL-DUPLEX 

FDX 

Off 

Connection in h f-duplex mode 

al

 

Ethernet Extender 

Remote The device operates in remote mode 

Local 

The device operates in local mode 

Error Error 

occurred 

Link 

A valid connection established 

Green, 1Mbps, up to 1900M 
Amber, 3Mbps, up to 1800M 

Green, 5Mbps, up to 1600M 
Amber, 10Mbps, up to 1400M 

Green, 15Mbps, up to 1200M 
Amber, 20Mbps, up to 1000M 

Green, 25Mbps, up to 800M 
Amber, 30Mbps, up to 700M 

Green, 40Mbps, up to 600M 
Amber, 50Mbps, up o 300M 

 t

 

 

Functional Description 

 

Meets NEMA TS1/TS2 Environmental requirements: temperature, shock, and vibration for traffic control equipment. 

 

Meets IEC61000-6-2 EMC Generic Standard Immunity for industrial environment. 

 

Operates transparent to higher layer protocols such as TCP/IP. 

 

Ethernet port: Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, full/half-duplex; Auto MDI/MDIX. 

 

Ethernet Extender port: Symmetrical on the VDSL, full-duplex 50Mbps communications link over existing copper telephone line. 

 

One DIP switch for configuring Local (Loc) and Remote (Rmt). 

  Ten speeds with speed indicator LEDs on front panel of unit, up to 50Mbps @ about 300meters (984ft.), down to 1Mbps @ about 

1,900meters (6,233ft.). 

 

Operating voltage and Max. current consumption: 0.35A @ 12VDC, 0.175A @ 24VDC. Power consumption: 4.2W Max. 

  Power Supply: Redundant 12-30VDC Terminal Block power inputs and 12VDC DC JACK with 100-240VAC external power supply. “For 

use with Model UP0351E-12P as power jack supply source by Universal Micro Electronics Co., Ltd.". 

 

Field Wiring Terminal: Use Copper Conductors Only, 14-24 AWG torque value 4.5 lb-in. 

 

Operating temperature range @ -40  to 75  (

-40

 to 167

). Tested for functional operation @ -40  to 

85  (

-40

 to 185

). UL508 

Industrial Control Equipment certified Operating Surrounding Air Temperature @ -34

 to 60

 (-29

 to 140

). 

 

Supports Din-Rail or Panel Mounting installation. 

 

Assembly, Startup, and Dismantling 

  Assembly: Place the Hardened Ethernet Extender on the DIN rail from above using the slot. Push the front of the Hardened Ethernet 

Extender toward the mounting surface until it audibly snaps into place. 

 

Startup: Connect the supply voltage to start up the Hardened Ethernet Extender via the terminal block (or DC JACK).   

 

Dismantling: Pull out the lower edge and then remove the Hardened Ethernet Extender from the DIN rail. 

 

 

 