Setting Up

 

1. One transmitter, multi receivers 

Turn all power switches on, all DMX indicator(s) should be off (If some DMX indicator is on or flash, press & 

hold the light’s FUNCTION button until it turns off); then press the transmitter’s FUNCTION button for one second, 

all the receivers will flash fast; then all get matched. 

 

2. Multi transmitters, multi receivers (e.g. 3 pair transmitter & receiver named A B C) have all power switches off. 

1) A pair power on, then follow the step 1 to get them matched. 

2) B pair power on, then follow the step 1 to get them matched. 

3) C pair power on, then follow the step 1 to get them matched. 

 

 

Disconnect the wireless transmitter 

1 Press and hold the transmitter’s FUNCTION button for 5 seconds, the transmitter will disconnect with all 

receivers. The DMX indicators on receivers will be off. 

 

 

Building a DMX-chain: 

 

Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always connect one 

output with the input of the next fixture until all fixtures are connected. 

Caution: 

At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 

Ω 

resistor between 

Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture. 

 

 

Only use a stereo-shielded cable and 3-pin or 5-pin XLR-plugs and connectors in order to connect the controller with the 

fixture or one fixture with another. 
 

Occupation of the XLR-connection: 

 

 

 

CLEANING AND MAINTENANCE 

We recommend a frequent cleaning. Please use a moist, lint-free cloth. Never use alcohol or solvents. 

 

The following points have to be considered during maintenance: 

1) 

All screws used for installing the devices or parts of the device have to be tightly connected and must not be 

corroded. 

2) 

There must not be any deformations on housings, fixations and installation spots (ceiling, suspension, trussing). 

3) 

The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments.  

 

 

There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are only to be 

carried out by authorized dealers. 

 

 