The PIR sensor scanning specifications
(approximately 12 metres at 120°) may vary slightly
depending on the mounting height and location.
The detection range of the unit may also alter with
temperature change. Before selecting a place to
install your PIR bulkhead you should note that
movement across the scan area is more effective
than movement directly towards or away from the
sensor. (refer to Fig. 2).
If movement is made walking directly towards or
away from the sensor and not across the apparent
detection range will be substantially reduced (refer
to Fig. 3).
iNtroductioN:
The bulkhead light incorporates a PIR (passive Infra
red) sensing device which continuously scans a
preset operating zone and immediately switches the
light on when it detects movement in that area.
This means that whenever movement is detected
within the range of the sensor the light will switch
on automatically to illuminate the area you have
selected to light. While there is movement within
range of the unit the light will remain on.
read tHiS firSt:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
this product must be installed by a competent
person in accordance with the current building
and iee wiring regulations.
As the buyer, installer and/or user of this product it
is your own responsibility to ensure that this fitting
is fit for the purpose for which you have intended
it. Eterna Lighting cannot accept any liability for
loss, damage or premature failure resulting from
inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal domestic service. Using
this fitting in any other environments may result in a
shortened working life.
Switch off the mains before commencing installation
and remove the appropriate circuit fuse or lock off
MCB.
This unit is suitable for outdoor use.
This product is designed for permanent connection
to fixed wiring: this must be a suitable circuit
(protected with the appropriate MCB or fuse).
Before making fixing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
Make sure that the fixings are strong enough to
support the considerable weight of the fitting and
hold it rigidly.
The lamp must be positioned so that there is at least
0.5m (500mm) between the bulb and any illuminated
surface.
When making connections ensure that the terminals
are tightened securely and that no strands of wire
protrude. Check that the terminals are tightened
onto the bared conductors and not onto any
insulation.
This product must be connected to earth
termination.
warNiNg:
This product becomes hot!
This product is not intended to be used by children
and persons with sensory, physical and/or mental
impairments that would prevent them from using it
safely.
imPortaNt:
Always switch off the mains power
before changing the lamp.
you are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out,
these tests are specified in the current IEE wiring and
building regulations.
wHere to fit your Pir BuLKHead:
To achieve best results we suggest you take the
following points into consideration:
Do not mount on a surface that has vibration.
Ideally the PIR bulkhead light should be mounted 1.8
to 2.5 metres (6 to 8ft) above the area to be scanned
(refer to Fig. 1 below).
To avoid damage to the unit do not aim sensor
towards the sun.
Avoid positioning the sensor unit adjacent to a
bright light source which may prevent the unit from
operating when the lux control is set to operate in
dark conditions.
Avoid nuisance false triggering by directing sensor
away from:
Trees and shrubs
Reflective surfaces such as smooth white walls
Swimming pools
Heat sources such as boiler flues
Blue
(power cable)
Yellow / Green
(power cable)
L
N
2.5M
4M
8M
12M
120˚
Appr.
TIME
LUX
Terminal Block
Diffuser
Lamp Holder
Mounting Screws (2Pcs)
Screwdriver
Brown
(power cable)
Screw (A)
Transparent
Plate
good
Less effective
iNStaLLatioN:
Blue
(power cable)
Yellow / Green
(power cable)
L
N
2.5M
4M
8M
12M
120˚
Appr.
TIME
LUX
Terminal Block
Diffuser
Lamp Holder
Mounting Screws (2Pcs)
Screwdriver
Brown
(power cable)
Screw (A)
Transparent
Plate
fig 4
When installing the PIR bulkhead light, please refer
to Fig. 4 above.
01) Switch off the mains power before commencing
installation.
02) Remove the diffuser using a screwdriver, see Fig.
4 above.
03) Unscrew the screw (A) and remove the
transparent terminal cover plate.
04) Position the fitting on the surface where its to be
installed and mark the mounting hole positions.
Drill and plug the wall at the marked positions
and pass cable wire through rubber grommet.
Screw and fix the lamp body to wall with suitable
mounting screws (supplied).
05) Connect the main power wires to the terminal
block (see the relative symbols - Fig. 4 above).
06) Insert the lamp into the (B22) lampholder.
07) Re-screw transparent plate.
08) Refit the diffuser.
09) Restore power, wait 30 seconds for circuit to
stabilise.
10) Set controls.
Blue
(power cable)
Yellow / Green
(power cable)
L
N
2.5M
4M
8M
12M
120˚
Appr.
TIME
LUX
Terminal Block
Diffuser
Lamp Holder
Mounting Screws (2Pcs)
Screwdriver
Brown
(power cable)
Screw (A)
Transparent
Plate
fig 1