Eterna EX360PIRWH Installation Instructions Download Page 2

EFFECTIVE:

Movement across

scan area

LESS EFFECTIVE:

Movement 

directly in front 

of scan area

INSTALLATION:

When installing the PIR sensor please refer to Fig. 4 

below.

01)  Switch off the mains before commencing 

installation.

02)  Unscrew the bottom screw and remove back 

plate.

03)  Using back plate as a template to mark the 

mounting surface.

04)  Drill and plug the fixing holes.

05)  Pass both the feed and load cables through the 

rubber grommet in the back plate. 

06)  Fix the back plate to the mounting surface 

with the screws supplied, noting the mounting 

direction (indicator on plastic back plate) 

.

07)  Connect the main cable and load cable to the 

terminal block (see Fig. 4 below) 

(Cable for 6A/230VAC: 3 cores not less than 

1.5mm

2

 conducting cross-sectional area, not 

included).

08)  Refit the terminal block.

09)  Fit the body to the back cover and secure using 

screw.

10) Restore mains power.

11)  Adjust the PIR sensor to desired working 

requirements.

SPECIFICATION:

•  Detection range: Approx. 12 metres at 240° 

(horizontal) and 130° (vertical)

•  Duration time: from 10(±5) seconds up to 4(±1) 

minutes adjustable

• Weatherproof: IP44

• Voltage: 230-240VAC~50Hz

• Fuse Rating: 6.3A/250VAC • 5x20mm

•   Wattage:   

Max. 1000W incandescent lamp (resistive load) 

Max. 300W fluorescent lamp (inductive load) 

Max. 150W LED (no more than 8 lights)

•  Lux Control Level: from daylight to night adjustable

 

READ THIS FIRST:

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, 

contact the outlet where you bought this product.

This product must be installed by a qualified 

electrician in accordance with the current 

building and IEE wiring regulations.

The installer must ensure that this fitting is suitable 

for the purpose intended. Eterna Lighting Ltd cannot 

accept any liability for loss, damage or premature 

failure resulting from inappropriate use.

This unit is suitable for outdoor use.

This product is designed for permanent connection 

to fixed wiring: this must be a suitable circuit 

protected with the appropriate MCB or fuse. 

This fitting is double insulated and does not require 

an earth (however there is an earth post for earth 

continuity).

 

INTRODUCTION:

The PIR (passive Infrared) sensing device 

continuously scans a preset operating zone and 

immediately switches the load-light on when it 

detects movement in that area. While there is 

movement within range of the unit the load light will 

remain on.

WHERE TO FIT YOUR PIR SENSOR:

To achieve best results we suggest you take the 

following points into consideration:

Do not mount on a surface that suffers vibration.

The PIR sensor should be mounted 2.5 to 3 metres 

above the area to be scanned (refer to Fig. 1 below).

To avoid damage to the unit do not aim the sensor 

eyeball towards the sun.

Avoid positioning the sensor unit adjacent to a 

bright light source which may prevent the unit from 

operating when the lux control is set to operate in 

dark conditions.

Avoid nuisance false triggering by directing sensor 

away from: 

• Trees and shrubs  

• Reflective surfaces such as smooth white walls 

• Swimming pools and ponds 

• Heat sources such as boiler flues

The PIR sensor detection range may vary slightly 

depending on the mounting height, location and 

temperature changes.

For optimal performance ensure your sensor is 

installed where pedestrian traffic crosses the 

detection zone (refer to Fig. 2 opposite). Note that 

movement directly towards or away from the sensor 

is less effective in triggering the sensor. (refer to Fig. 

3 opposite).

N

2.5-3M

4M

8M 12M

240˚

Appr.

Power

Cable

Mounting

Screws x 2

Load

Cable

130˚

Appr.

N L L

Terminal Block

L

L

Earth

Blue (PIR)

Brown (PIR)

Black (PIR)

230VAC 50Hz

Main Power

Back

Plate

+

_

TIME

LUX

+

_

TIME

LUX

Fig 2

Fig 3

Fig 4

2.5-3m

4M

8M

12M

Fig 1