9. Thread the supply cable into the connection box 

  and make the connections according to the colour 

  code listed opposite and observing the terminal 

  identification markings inside the connection box.

10.  Push the rubber gland and nut back along the 

cable until they locate in the threaded cable entry 

and tighten the nut sufficiently to grip the cable 

and make the entry water-tight. Do not over-

tighten.

11.  Replace the connection box cover and replace the 

four screws. Ensure that the sealing gasket is 

correctly positioned.

12.  Adjust the position of the light so that it illuminates 

the desired area and limiting the spread of light 

onto neighbouring property.

13.  Tighten the bracket fixing screws on the side of the 

fitting to lock in position.

14.  Undo the screw at the top of the glass safety shield 

on the front of the light fitting and allow to hang 

from the hinge.

15.  Carefully remove the lamp from the box taking care 

not to touch it with bare hands.

16.  Using a soft, dry, clean cloth, grip the lamp and fit it 

between the sprung contacts in the lampholder.

17.  Close the glass safety shield and tighten the screw. 

Ensure that the waterproofing gasket in correctly 

positioned.

18. Restore the power and switch on.

Specification

 

 

Voltage:

  220-240 V  50 Hz 

Weatherproof:

  IP44 

Class I Protection:  

Class I / Earthed

Safety Markings:

Cleaning

Disconnect the power and clean the exterior only of 

this fitting with a moist (not wet) cloth.

Do not use any chemical or abrasive cleaners.

Lamp Replacement

1. Switch off the electricity at the mains.

2.  Allow to cool down then undo the screw at the top 

of the glass safety shield and allow to hang down 

on the hinge.

3.  Remove and replace lamp making sure it is of the 

same type and wattage as stated on the re lamping 

label, do not touch with bare fingers, grip the lamp 

with a tissue or clean soft cloth.

4.  Replace the glass safety shield and tighten the 

retaining screw. Ensure that the gasket is positioned 

correctly

5. Restore the power and switch on.

Replacement Lamp Type

   

   ETH120L/LWH 

   ETH400L/LWH

Wattage:   

120W 

 

400W 

Supply Voltage: 

 240V 

Type: 

 

 Double ended linear Halogen

General Information, Safety and Installation Instructions

Read this first

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, contact 

the outlet where you bought this product.

This product contains glass, care must be taken when 

assembling, fitting or handling to prevent personal 

injury or damage to the product.

This light fitting must be installed by a competent 

person in accordance with the Building Regulations 

making reference to the current edition of the IEE 

Wiring Regulations (BS7671). The Building Regulations 

may be obtained from HMSO or viewed and 

downloaded from www.communities.gov.uk following 

the link for Building Regulations.

As the buyer, installer and/or user of this product it is 

your own responsibility to ensure that this fitting is fit 

for the purpose for which you have intended it. Eterna 

Lighting cannot accept any liability for loss, damage or 

premature failure resulting from inappropriate use.

If in any doubt, consult a qualified electrician.

The lamps (bulbs/tubes) supplied with this fitting are 

consumable parts and therefore may be outside of any 

warranty offered.

Switch off the mains before commencing installation 

and remove the appropriate circuit fuse.

When working at heights, please use a suitable 

platform. 

Disconnect the fitting from the electrical supply before 

flash or high voltage testing.

Suitable for outdoor use.

This product is suitable for installation on surfaces 

with normal flammability e.g. wood, plasterboard, and 

masonry.  It is not suitable for use on highly flammable 

surfaces (e.g. polystyrene, textiles). 

Before making fixing hole(s), check that there are no 

obstructions hidden beneath the mounting surface 

such as pipes or cables.

The chosen location of your new fitting should allow 

for the product to be securely mounted and safely 

connected to the mains supply (lighting circuit).

When choosing the location for your new fitting, 

ensure that the fixings will be anchored in a solid 

surface e.g. concrete, brick or a joist—do not fix directly 

onto panelling, cladding, plasterboard etc.

If the location of your new fitting requires the provision 

of a new electrical supply, the supply must conform 

with the requirements of the Building Regulations 

making reference to the current edition of the IEE 

Wiring Regulations (BS7671).

This product is designed for permanent connection to 

fixed wiring: this should be either a suitable lighting 

circuit (protected with a 5 or 6 Amp MCB or fuse) or a 

fused spur (with a 3 Amp fuse) via a fused connection 

unit.

We recommend that the supply incorporates a switch 

for ease of operation.

Make connections to the electrical supply in 

accordance with the following code:

Live - Brown or Red 

Neutral - Blue or Black 

Earth - Green and Yellow

When making connections, ensure that the terminals 

are tightened securely and that no strands of wire 

protrude. Check that the terminals are tightened onto 

the bared conductors and not onto any insulation.

This product must be connected to Earth.

IMPORTANT— Always switch off at the mains before 

changing the lamp.

You are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation there 

are electrical tests that should be carried out: these 

tests are specified in the Wiring Regulations (BS7671) 

referred to in the Building Regulations. If in doubt, 

consult a qualified electrician.

Installation

1. Choose the location for your new floodlight giving  

  consideration to the points above.

2. Remove the bracket from the light by removing the  

  screws and nuts on each side

3. Fix the bracket to the mounting surface using a spirit  

  level (if available) to ensure that the bracket is 

  fixed level and using appropriate fixings (not  

  supplied).

4. Attach the light fitting to the bracket using the 

  screws, washers and nuts you removed earlier.

5. Rotate the fitting in the bracket so that the light 

  faces directly downwards, this will give you easy 

  access to the connection box from above.

6. Remove the cover from the connection box by 

  removing the four screws and lifting off.

7. Remove the gland nut from the side of the 

  connection box and thread your supply cable 

  through.

8. Remove the rubber gland from the cable entry on 

  the side of the connection box and thread onto the 

  cable.

Installation Instructions and Care

                       

                       