STEP 1
STEP 2
General Information & Installation:
Cleaning & Installation Diagrams:
READ THIS FIRST:
Check the pack and make sure you have all of the
parts listed on the front of this booklet. If not, contact
the outlet where you bought this product.
This poduct must be installed by a competent
person in accordance with the Building
Regulations.
As the buyer, installer and/or user of this product it is
your own responsibility to ensure that this fitting is fit
for the purpose for which you have intended it. Eterna
Lighting cannot accept any liability for loss, damage or
premature failure resulting from inappropriate use.
If in any doubt, consult a qualified electrician.
Switch off the mains before commencing installation
and remove the appropriate circuit fuse or lock off
MCB.
The batteries supplied with this fitting are consumable
parts and therefore may be outside of any warrant
offered.
The unit is suitable for outdoor use.
This product is suitable for installation on surfaces
with normal flammability (indicated by the “F” in a
triangle) e.g. wood, plasterboard, masonry. It is not
suitable for use on highly flammable surfaces (e.g.
polystyrene, textiles).
Before making fixing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
The chosen location of your new fitting should allow
for the product to be securely mounted or suspended
and connected to an apprprate mains supply (lighting
circuit).
When making connections, ensure that the terminals
are tightened securely and that no strands of wire
protrude.
Check that the terminals are tightened onto the bared
conductors and not onto any insulation.
This product must be connected to earth termination.
IMPORTANT - Always switch off mains power
before opening fitting.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out:
these tests are specified in the current IEE Wiring and
Building Regulations.
If in doubt, consult a qualified electrician.
INSTALLATION:
1) Choose the location of your new fitting giving
consideration to all of the conditions listed above.
2) Push down the gear tray and rotate the clip
clockwise to align with the slots in the gear tray.
Repeat on the other side of the gear tray. See
Fig. 1.
3) If fixing direct to a mounting surface, clear through
the four mounting holes on the back of the fitting,
visible from the outside, using a 5mm drill - see
Fig. 2.
4) Using the back of the fitting as a template, mark
the location of the fixing holes on your mounting
surface.
5) If fixing directly to a solid surface, drill and plug as
required.
6) Secure your fitting in position using the screws and
washers supplied. Put the washer onto the screw
before fixing.
7) Hanging clips are supplied (Fig. 2) to allow you to
suspend the fitting from chains (not supplied).
8) Ensure that the chain is strong enough to support
the weight of the fitting and that the tops of the
chains are fixed securely to the mounting surface.
9) Pierce the centre of the soft grommet at the end of
the fitting adjacent to the supply wiring. Take care
not to make the hole too large as the tight fit of
the grommet to the cable is essential to maintain
its IP rating. Alternatively, fit a gland/nut assembly.
10) On the white metal gear tray, locate the
lampholders in the rectangular slots at each end
of the fitting. The lampholders must be positioned
so that the slots on each lampholder face the
centre of the fitting. (Fig. 3).
11) Thread the supply cable through the gland.
12) Make connections with un-switched mains supply
to terminals L E N (Fig. 5).
13) To operate the fitting in non-maintained mode,
remove the link from the terminals “L and L1”
(Fig. 5).
14) If the lamp is to be switched, remove the link wire
from between the terminals marked “L and L1”
and connect your switched wire to L1 (Fig. 5).
15) Mark the current date on the battery pack.
16) Connect the battery pack via the plug and socket.
17) Refit the gear tray locking into position by rotating
the clips see Fig. 1 step 2.
18) Fit the fluorescent tube(s) (not supplied) by
pushing the pins into the slots in the lampholders
and turning the tube through 90° or until it clicks
into position.
19) Click all clips into place in bottom housing (Fig.
4 step 1).
20) Hold the diffuser in position on the fitting so that
it is seated on the soft foam gasket all the way
around.
21) Position the bottom of each fixing clip in the lip
of the diffuser and press the thumb catches up
and over to lock firmly in position. (Fig. 4 step 2
and 3).
22) Restore the power supply, switch on and also
check the charging circuit via the green LED is
operational.
Fig. 5
Fig. 4
STEP 1
Click clip
in to place
Lift clip up and lock down into place
STEP 2
Clear through using a
5mm diameter drill
Fig. 2
Sliding bracket
Fig. 1
Make sure the
latch has lined up
with the hole
before clipping the
plate in to place
Push latch clockwise
Push down
hard here on
the plate to get
to the latch
Gear tray is held
on by a retaining
strap which can be
removed if required
Fig. 3
Push the lamp
holder upwards
until it clicks in
to place
Push clip
in to lock
STEP 3
CLEANING:
Disconnect the power and clean the exterior only of
this fitting with a moist (not wet) cloth.
The diffuser may be removed and washed in a mild
detergent solution. Make sure it is completely dry
before putting back on your fitting.
Do not use any chemical or abrasive cleaners.
Un-switched Mains
Blue
(Neutral)
Yellow/Green
(Earth)
Brown
(un-switched)
Brown
(switched)
������
������
������
�
�
��
�
�
��
������������
�������
����
���������
�����
�������������
�����
����������
�����������������
������
������
����������