Safety markings:

 

Read this first: 

 

>

If in any doubt, consult a qualified electrician.

 

>

Suitable for indoor use only. 

>

Suitable for fixing on a normally flammable surface. 

>

Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting 
surface such as pipes or cables. 

>

If the location of your new fitting requires the provision of a new electrical supply, the supply must 
conform with the requirements of the latest edition of the IEE wiring regulations. 

>

Make connections to the electrical supply in accordance with the following code: 

                               Live - Brown or Red 
                               Neutral - Blue or Black 

>

This product is designed for permanent connection to fixed wiring: this should be either a suitable 
lighting circuit ( protected with a 5 or 6 Amp MCB or fuse ) or a fused spur ( with a 3 Amp fuse ) via 
a  fused  connection  unit.  We  recommend  that  the  supply  incorporates  a  switch  for  ease  of 
operation. 

>

This fitting is double insulated, do not connect any part to earth. 

>

Ensure that the minimum distance from the light to any flammable surface is at least 40mm. 

>

If in any doubt, consult a qualified electrician.

 

 
 

Installation: 

 

1) Turn off the electrical supply and remove the appropriate circuit fuse. 

2) Choose the location of your pygmy light so that the movement of the switch is within the 

ranges shown in the diagram opposite. 

3) Ensure that there is at least 40mm between the fitting and any overhanging or 

horizontal surface. See diagram opposite. 

4) Secure the fitting in place using screws appropriate to the mounting surface. 

5) Using cable clips for 2 x 0.75mm² flat twin flex, secure the cable to the mounting 

surface choosing a route which prevents the cable from fouling the movement of 

whatever you have planned to actuate the switch. 

6) Using an Eterna ® Link lead ( not supplied ), make your connection to the mains 

supply. See above for wiring colour code. 

7) Fit the 15 Watt pygmy lamp supplied. 

8) Restore the power and switch on. 

 

40

m

m

ON—1.5mm 

OFF—5.0mm 