MULTI-FUNCTION SENSOR 

SPECIFICATIONS:

 

UNDERSTANDING THE CONTROLS:

Refer to the table (fig. 1) below.
The sensor is an active motion detector: it emits a 

high frequency electromagnetic wave 5.8GHz and 

receives its echo. The sensor detects the change 

in echo from movement in its detection zone. A 

microprocessor then triggers the switch light ON 

command. Detection is possible through doors, 

panels of glass and thin walls.

 

DETECTION AREA:

This determines the effective range of the motion 

detector and is set up by DIP switches at the sensor, 

refer to fig. 2 opposite. Note that reducing the 

sensitivity will also narrow the detection range.
The following settings are available:
I - Detection Range 100% 

II - Detection Range 75% 

III - Detection Range 50% 

IV - Detection Range 10%

 

 

HOLD TIME:

This determines the time the fitting remains at 

100% level on motion detection and is set with DIP 

switches at the sensor, refer to fig. 2 opposite. The 

walk test setting is useful when installing the fitting 

to establish correct operation and range.
The following settings are available:
I - Walk test mode 5s 

II - 90s 

III - 3 minutes 

IV - 10 minutes

DAYLIGHT SENSOR:

This setting holds off the 100% light output should 

there be sufficient daylight and is set using DIP 

switches at the sensor, refer to fig. 2 opposite.
The following settings are available:
I - Photocell disabled 

II - 50 lux twilight operation 

III - 15 lux twilight operation 

IV - 5 lux darkness operation only
* In daylight setting the lamp(s) will always be on  

with motion detected and operate at 100% light  

output, even in bright daylight.

 

 

CORRIDOR FUNCTION:

This setting determines how long the fitting should 

operate at 10% output after the hold time has 

elapsed and is set by DIP switching at the sensor, 

refer to fig. 2 opposite.

NOTE:

 Setting at 0s disables this function; setting 

at + 

 leaves it permanently at 10% output until 

activated again.
The following settings are available:
I - 0s 

II - 30s 

III - 10 minutes 

IV - + 

Detection Area

Hold Time

Daylight Sensor

Corridor Function

1

2

3

4

5

6

7

8

I

ON

ON 100%

I

ON

ON

5s

I

ON

ON

Disable

I

ON

ON

0s

II

-

ON

75%

II

-

ON

90s

II

-

ON 50Lux

II

-

ON

30s

III

ON

-

50%

III

ON

-

3min

III

ON

-

15Lux

III

ON

-

10min

IV

-

-

10%

IV

-

-

10min

IV

-

-

5Lux

IV

-

-

ON

OFF

Model number

MLC16C-P

Operating voltage

220-240Vac, 50/60Hz

Output constant current

300mA / 350mA, set via DIP 

switch

Output voltage

28-48Vdc

Efficiency

≥80%

Power factor

≥0.9

HF system

5.8GHz ± 75MHz, ISM wave 

band

Transmitting power

<0.5mW

Detection zone max. 

16m (D) x 6m (H)

Dectection sensitivity

10% / 50% / 75% / 100%

Hold time

5s / 90s / 3 min / 10 min

Corridor function

0s / 30s / 10 min / Disable

Daylight sensor

5lux / 15lux / 50lux / Disable

Standby dimming level

10% - can be customised

Mounting height

6m Max.

Motion detection

0.5~3m/s

Detection angle

150° (wall installation)  

360° (ceiling installation)

Fig 1

Detection 

Area

Daylight 

Sensor

Hold 

Time

Daylight 

Sensor

Corridor 

function

Fig 2

RED DIRECTIVE 

           Eterna Lighting Ltd

Microwave Occupancy Sensor

Full declaration available at www.eterna-lighting.co.uk