ETEL Doc. - Operation & Software Manual # DSC2P 903 / Ver. F / 3/6/05
Chapter E: Appendixes
Operation & Software Manual
Direct Drives & Systems
235
15.4 CAM example
:10.0
;Label 10
PWR.0=1
;Power on
WTM.0
;Waits until the movement is finished
IND.0
;Starts the homing
WTM.0
;Waits until the movement is finished
SPD.0=360.0
;Sets the maximum speed to 360 (ISO unit)
ACC.0=200.0
;Sets the maximum acceleration to 200 (ISO unit)
:30.0
;Label 30
POS.0=360.0
;Goes to the position 360 (ISO unit)
WTM.0
;Waits until the movement is finished
CAL.0=60
;Calls the subroutine 60
POS.0=30.0
;Goes to the position 30 (ISO unit)
WTM.0
;Waits until the movement is finished
CAL.0=70
;Calls the subroutine 70
JMP.0=30
;Jumps to label 30
:60.0
;Label 60
CAM.0=20
;Global diminution to 20% of speed, acceleration and increases the waiting time (refer
to
WTT.0=1.0
;Waits for 1 (ISO unit)
RET.0
;Returns to the calling routine
:70.0
;Label 70
CAM.0=100
;Sets the default value of the CAM (no diminution of speed and acceleration)
WTT.0=3.0
;Waits for 3 (ISO unit)
RET.0
;Returns to the calling routine