-6-
3. Specifications
Instrument safety
: IEC/EN61010-1, IEC/EN6010-2-032
Insulation
: double insulation
Pollution degree
: class
II
Overvoltage category
: CAT III 150V to ground, Max 20A
Degrees of protection
:
-IP30, Group III equipment as per EN 60529 Ed 92
-IK04, as per EN 50102 Ed 95
Dimensions
(L
×
W
×
H):
-Long elliptic jaw: 285mm
×
90mm
×
66mm; (11
×
4
×
3 inches)
-Round jaw: 260mm
×
90mm
×
66mm;(10
×
4
×
3 inches)
Span of Jaw
: Long elliptic jaw 35mm; round jaw 32mm
Weight
(including batteries):
Long elliptic jaw-1160g, Round
jaw-1120g
Battery type
: 4
×
1.5V alkaline LR6 AA battery
Low battery indication
:
is displayed
Internal consumption
: <50mA
Auto Power off
: after 5 minutes of idleness
Display
: 4 LCD, sign, decimal point and backlight
Memory size
: 99 Units of Reading
Environment
(Temperature & Relative Humidity):
-Working: -10
°
C~55
°
C, 10%RH-90%RH
-Storage: -20
°
C ~60
°
C, below 70%RH
Range shift:
Full range automatic shifting
External magnetic field:
<40A/m
External electric field:
<1V/m
Data upload interface:
RS232 (Optional)
Summary of Contents for ETCR2000+