-15-
Phase
Relationship
Phase Value
Phase
Relationship
Phase Value
Ua-Ub 120°
Ia-Ib 120°
Ub-Uc 120°
Ib-Ic 120°
Uc-Ua 120°
Ic-Ia 120°
6
.
Three-phase three-wire (Phase of a balanced threephase load)
:
Phase
Relationship
Phase Value
Phase
Relationship
Phase Value
Uab-Ucb 300°
Ia-Ic 240°
Uab-Ia 30°
Ucb-Ic 330°
7
.
T
hree-phase four-wire vectogram and
T
hree-phase three-wire
vectogram
:
Three-phase four-wire vectogram Three-phase three-wire vectogram
If the direction of current clamp or current line is
reversed there’s a phase value difference of 180 °, viz.
adding 180°to the standard value.