12
P-TS7 User Manual
Note:
Only one Paradigm Touchscreen Remote App connection is allowed per P-TS7
touchscreen at any given time.
• Mobile App Connection this setting toggles On/Off the ability for the Paradigm
Touchscreen Remote App to connect to this P-TS7. This setting is Off by default.
Note:
The following settings are available for configuration when the Mobile App
Connection setting is set to On.
• Passcode is a four-digit numeric code used to secure a connection to the touchscreen
from the Touchscreen Remote App. On initial setup, the P-TS7 will automatically
generate a random four-digit code, alternatively you can choose your own four-digit
code, or leave the field blank to disable the passcode requirement.
Note:
A passcode may be required when connecting to the P-TS7 using the
Touchscreen Remote App.
• Port: UDP port. The port defaults to 49044.
•
Tip:
When the UDP port is not default (49044), you must specify the
port number with the IP address in the Touchscreen Remote App. For
example, 10.101.15.101:49045.
• Pressing the {Reset to Defaults} button resets the Mobile App Settings to factory
defaults:
‐
Toggles the Mobile App Connection Off.
‐
Resets the passcode to a new random four-digit code.
‐
Resets the Port to 49044.
Summary of Contents for Unison Paradigm P-TS7