background image

E T C   I n s t a l l a t i o n   G u i d e

AV/Serial Interface Station

Unison

®

  Heritage  AV/Serial  Interface  Station

Page 3 of 3

Electronic Theatre Controls, Inc.

Install the Station into the Backbox

Spacers are provided in the termination kit to help align the station and cover flush against the wall in 
flush mount applications.The spacers are not needed on surface mount backboxes.

Step 1:

Insert the station electronics and wiring into the backbox. The arrow on the mounting plate 

must point up.

Step 2:

If needed, fold the spacer in a zigzag fashion and press together to achieve the required 
thickness to fill the gap between the station and backbox. Cut off and discard the excess 
material and place the spacer between the station and backbox.

Step 3:

Secure the station to the backbox with the two screws provided. If using spacers, the 
screws install through them.

Install the Faceplate

The faceplate is secured to the station with two magnets that are located on the bottom side of the 
faceplate.

Step 1:

Align the top of the faceplate approximately 20 degrees from the station.

Step 2:

Hook the top of the faceplate to the tabs located on the station electronics assembly. To 
ensure the faceplate is hooked properly on the top hook, wiggle it slightly side to side 
while the bottom is angled 20 degrees from the wall.

Step 3:

Swing the bottom of the faceplate down until the magnets engage.

Step 4:

If the faceplate does not fully attach automatically, wiggle the bottom of the faceplate until 
the magnets are seated properly to the station and the faceplate is secure.

N o t e :

For some flush mount applications with certain trim rings it may be necessary to 

remove the station’s back cover before installation into the backbox.

N o t e :

To improve successful station and wall plate installation, do not overtighten the 

screws.

Reviews: