23
TurboRay User Manual
View Temperatures
Navigate: Main Menu
→
Diagnostics
→
Temperatures
Displays the current measured temperature for the internal fixture attributes (Main Menu
→
Diagnostics
→
Temperatures
→
PCB Temperatures) such as the display, motor driver, and LED
driver boards. Separately, temperature information is available for the LED Sensors (Main Menu
→
Diagnostics
→
Temperatures
→
LED Sensors) on each of the light engines.
View DMX Monitor
Navigate: Main Menu
→
Diagnostics
→
DMX Monitor
Displays the current DMX value for each of the fixture's channels (parameters of the fixture).
Scroll the list to view all available parameters. DMX data is not available when DMX is not
connected.
View Software Version
Navigate: Main Menu
→
Diagnostics
→
Software Version
Displays the current software version for the fixture, including the display board, fixture pan /
tilt, motor driver boards, and the LED driver boards.
View Device
Navigate: Main Menu
→
Diagnostics
→
Device
Displays the fixture RDM and IP address information (read only).
•
RDM Device Label - a compatible RDM controller can read and write the device label
•
RDM Device ID - this is a unique device ID
•
IP Address - this is the address assigned in the Main Menu
→
Settings
→
Control
→
Network
→
Set IP Address menu.