Page 1: ...Part Number 7064M1200 Rev B Released 2018 08 Source Four Fresnel User Manual...
Page 2: ...and other countries All other trademarks both marked and not marked are the property of their respective owners ETC intends this document whether printed or electronic to be provided in its entirety T...
Page 3: ...Table 2 Installing and Replacing the Lamp 3 Adjusting the Field Angle 5 Using Accessories 6 Adjusting the Yoke 8 Adjusting the Yoke Balance Point 8 Adjusting the Fixture Angle 8 Replacing the Lens 9 R...
Page 4: ...ii Source Four Fresnel User Manual...
Page 5: ...f the power lead cordset is damaged it must be replaced Do not mount the fixture on or near combustible surfaces Do not operate the fixture without a lens installed Always hang the fixture with the ac...
Page 6: ...115 375 115 10 540 3 250 K 300 hours HPL 375 115X 375 115 8 000 3 050 K 1000 hours HPL 750 120 750 120 21 900 3 250 K 300 hours HPL 750 120X 750 130 16 400 3 050 K 1500 hours HPL 575 120 575 120 16 52...
Page 7: ...nterclockwise one quarter turn and remove from the fixture Figure 3 Remove lamp with quarter turn counterclockwise Note Verify that the HPL lamp you intend to install is suitable for your facility s v...
Page 8: ...socket 10 Turn the lamp holder assembly clockwise one quarter turn so that the arrow points to the lock icon 11 Turn the knurled knob clockwise to secure the lamp holder assembly 12 Close the lamp ho...
Page 9: ...gle turn the field angle adjustment knob counterclockwise To enlarge the field angle turn the field angle adjustment knob clockwise Figure 5 Field adjustment from flood to spot 3 To lock the field ang...
Page 10: ...sories are locked in position with the accessory door before hanging the fixture Accessories such as barn doors and color scrollers must be secured with safety cables to the mounting position such as...
Page 11: ...e door in place Note Use only color frames or accessories with a 7 5 inch mounting flange Note The performance of saturated colors may be less than desirable in any theatrical lighting fixture especia...
Page 12: ...andle on the rear of the unit Figure 9 Yoke balance and angle adjustment 2 Loosen the yoke locking knob so that the fixture moves freely 3 Slide the fixture back and forth until it is properly balance...
Page 13: ...45 3 Use a flat blade screwdriver to slide the two plastic lens retaining clips on each side of the lens outward to release the lens Figure 10 Lens retaining clip 4 Allow the top of the lens to drop...
Page 14: ...ehind the lamp You must remove the lamp before cleaning the reflector Remove dust with a blast of oil free air or wipe with a clean lint free cloth You can use isopropyl alcohol distilled water or a 5...
Page 15: ...Replacing the Lens 11...
Page 16: ...111 683 Service UK service etceurope com Holzkirchen DE Tel 49 80 24 47 00 0 Service DE techserv hoki etcconnect com Hong Kong Tel 852 2799 1220 Service Asia service etcasia com Web etcconnect com 20...