ETC

Configuration

You can perform the following tasks using the built-in interface on the SMPTE Gateway. Additional 
configuration of the SMPTE Gateway is done using ETC Concert software. Refer to the SMPTE Gateway 
device-specific Help in Concert for more information.

View Device Information

The home screen provides the gateway name and IP address, as well as the last received timecode value.

To view additional information about to your gateway, select the About menu from the home screen. From 
the About menu, you can select one of the following two options:

• Version - Provides the version of software running on the device
• SMPTE - Provides the last received timecode value, input status and the frame rate of the source 

timecode

Lastly, to view or change the the SMPTE Source ID, select Setup > Source IDs from the home screen.

Configure Network Settings

To configure the network settings for your device, perform the following steps:

1:

From the home screen, select Setup > Network.

2:

From the Mode screen, you can use the up and down buttons to select Manual, Link Local or 
Automatic.

- Automatic will attempt to automatically configure the IP address, Subnet, and gateway for your 

device via DHCP.

- If you select Manual, you must configure the IP Address, IP Subnet, and IP Gateway screens and 

then select OK from the Apply/Reboot? screen.

- If you select Link Local, you can have the addressing done using your system’s link local addressing 

mechanism. Select OK from the Apply/Reboot? screen.

If your network settings are not valid after configuration, a warning appears for 3 seconds and then you are 
returned to the Mode screen and can try again.

Modify Device Settings

To restore the factory defaults or upgrade the software for your device, select the Operations menu from 
the home screen. From the Operations menu, you can select one of the two options:

• Restore Defaults - Select OK? from the Restore Defaults screen to restore all default values to your 

device. This removes all network and master/backup information that is configured for your gateway 
but retains the gateway name.

• Update Software - Select OK? from the Update Software from server <#.#.#.#> screen if you need 

to update the software directly from the gateway.

If you do choose to update directly from the gateway, the bootloader runs and the latest software is 
downloaded from the server indicated by the <#.#.#.#> IP address on the Update Software screen. If you 
need to modify this IP address, you can configure it in Concert software using the Update Server property.

Note:

The recommended method of updating the SMPTE gateway is through UpdaterAtor. 

Regardless of whether you update from UpdaterAtor or directly from the gateway, the 

device must be on the network.

Summary of Contents for Response SMPTE

Page 1: ...ion of the SMPTE gateway LED Indicators Power solid blue indicates that power is supplied Network solid green indicates network connection and blinking indicates network activity USB solid green indicates USB connection and solid red indicates connection without having fully detected identified and loaded device drivers Action Buttons Up Down Back buttons The Back button allows you to return to th...

Page 2: ...n this scenario the USB connection must be made directly to the lighting console Switching the Network Port Rack Mount Only The rack mount variant of the SMPTE gateway can have the Ethernet connector installed on the front or back of the unit To switch the location perform the following steps 1 Using a Phillips screwdriver remove the four screws on the bottom of the gateway and slide the cover off...

Page 3: ...ings is set to the same ID as the Source ID entered in your Event List Using SMPTE in Eos Event Lists You can trigger events in Eos from SMPTE using Show Control Event Lists For additional information on event lists in Eos refer to the Eos Family Operations Manual 1 On your console navigate to the Show Control tab and create a list 2 In the Type field enter SMPTE 3 In the Source field For SMPTE ov...

Page 4: ...nual you must configure the IP Address IP Subnet and IP Gateway screens and then select OK from the Apply Reboot screen If you select Link Local you can have the addressing done using your system s link local addressing mechanism Select OK from the Apply Reboot screen If your network settings are not valid after configuration a warning appears for 3 seconds and then you are returned to the Mode sc...

Page 5: ...gateways for mounting into a standard 19 rack enclosure If you only need to mount one unit a blanking plate is provided with the kit This blanking plate can be installed on either side of the rack mount bracket Hanging Hardware Kit 4260K1005 The Hanging Hardware Kit allows pipe mounting of a gateway in a variety of orientations You can vary the way the U bolt or c clamp attaches to the bracket and...

Reviews: