ETC Installation Guide

P-NSPS-D

Configuration

When the Network Station Power Supply is connected to the P-ACP, the
display will show the assigned IP address. An error will display in the Status
screen when the P-NSPS-D is not connected, has never connected, or the
communications to a P-ACP are interrupted. See

Menu on the next page

for

more information.

Processor assignment and

Preferences

are accomplished using Paradigm

LightDesigner configuration software. Reference the Paradigm LightDesigner
online help system for details.

Preferences

Preferences for the Network Station Power Supply, such as inactivity time, are
set in the LightDesigner configuration file and sent to the power supply when
the P-ACP establishes communication.

Remove P-NSPS-D from DIN rail

If for any reason you need to remove the Network Station Power Supply from
the DIN rail, follow these instructions.

1. Turn off power (at the source) to the 48 VDC Power Supply.
2. Disconnect all wiring to the P-NSPS-D.
3. Grip the P-NSPS-D and in one motion, slide it straight up and pivot the

top of the unit off of the DIN rail.

P-NSPS-D

Page 7 of 8

ETC

Summary of Contents for P-NSPS-D

Page 1: ...e LinkConnect station communication bus The Network Station Power Supply consists of two components that must be used together the DIN rail Network Station Power Supply that powers the station communi...

Page 2: ...r Supply voltage output terminals and the P NSPS D No other connections are supported Network Station Power Supply Input Use the ETC supplied 48 VDC power pigtail blue and black wire pair with the thr...

Page 3: ...comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is o...

Page 4: ...D a Run up to four LinkConnect data runs Belden 8471 or equivalent to the P NSPS D Strip 7 mm 1 4 in from the ends of each b Terminate the data wire typically white from one wire pair to terminal A a...

Page 5: ...ire into the L terminal and the neutral wire to the N terminal Secure each wire in place using a 3 mm slotted screwdriver Torque to 5 kgf cm 4 4 Lb in 7 Connect to the Paradigm control network by conn...

Page 6: ...resent in the system will display on the Status screen and will automatically clear themselves if the condition is resolved Error Description Resolution name Lost This P NSPS D has lost communication...

Page 7: ...ware Reference the Paradigm LightDesigner online help system for details Preferences Preferences for the Network Station Power Supply such as inactivity time are set in the LightDesigner configuration...

Page 8: ...ng Connected green Connected with Errors red a partial connection with bad comms Lost red comms activity is no longer present Unconnected red no comms present Main Menu About Setup File Operations Set...

Reviews: