Overview

The Network Station Power Supply

(P-NSPS-D) is a DIN rail mounted

power supply that powers up to
63 Paradigm stations or sensors over
the LinkConnect station
communication bus.

The Network Station Power Supply
consists of two components that must
be used together: the DIN rail Network Station Power Supply that powers the
station communication bus, and the DIN rail 48 VDC Power Supply that feeds
the DC power to it. This guide covers installation and basic setup of both
products.

Specifications

Note:

Installation must follow all national and local codes for

electrical equipment.

Environment

Ambient 0°C-50°C (32°F-122°F), 0-95% relative humidity (non-condensing)

Mounting

Vertically mount (only) on horizontal DIN rail (TS35 compatible).

Clearance

For best performance and to prevent overheating, leave a minimum clearance
between devices on the DIN rail. Clearance required: adjacent - 15 mm 
(0.6 in), above 40 mm (1.6 in), below 20 mm (0.8 in).

Important Safeguards

CAUTION:

For use in a controlled environment.

ATTENTION :

Pour une utilisation dans un environnement

contrôlé.

Summary of Contents for P-NSPS-D

Page 1: ...e LinkConnect station communication bus The Network Station Power Supply consists of two components that must be used together the DIN rail Network Station Power Supply that powers the station communi...

Page 2: ...r Supply voltage output terminals and the P NSPS D No other connections are supported Network Station Power Supply Input Use the ETC supplied 48 VDC power pigtail blue and black wire pair with the thr...

Page 3: ...comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is o...

Page 4: ...D a Run up to four LinkConnect data runs Belden 8471 or equivalent to the P NSPS D Strip 7 mm 1 4 in from the ends of each b Terminate the data wire typically white from one wire pair to terminal A a...

Page 5: ...ire into the L terminal and the neutral wire to the N terminal Secure each wire in place using a 3 mm slotted screwdriver Torque to 5 kgf cm 4 4 Lb in 7 Connect to the Paradigm control network by conn...

Page 6: ...resent in the system will display on the Status screen and will automatically clear themselves if the condition is resolved Error Description Resolution name Lost This P NSPS D has lost communication...

Page 7: ...ware Reference the Paradigm LightDesigner online help system for details Preferences Preferences for the Network Station Power Supply such as inactivity time are set in the LightDesigner configuration...

Page 8: ...ng Connected green Connected with Errors red a partial connection with bad comms Lost red comms activity is no longer present Unconnected red no comms present Main Menu About Setup File Operations Set...

Reviews: