Irideon WLZ User Manual
19
Initial Power Up
Track-Mount, Portable, and Canopy (DMX)
Fixtures
Control and configure the fixture over a DMX/RDM control network or
directly from a connected computer running appropriate software. When
controlling the fixture directly from a PC, a Gadget II interface or
DMX/RDM gateway is required.
Note:
Changing the address via RDM will override the local DMX
addressing dials. However, if you change the addressing dials after
you set the address via RDM, the addressing dials will override the
RDM setting. See
Set the DMX Address at the Fixture on page 16
.
Canopy (0–10 V) Fixture
Apply power and dim the fixture using a 0–10 V controller.
Note:
The 0–10 V driver conforms to IEC 60929 Annex E. Of the
0–10 V range, use 0–1 V to set the minimum level, and use 1–10 V
for continuous dimming.
Canopy (DALI) Fixture
Use a DALI configuration and commissioning tool to configure the DALI
address of the fixture.
Status LED
The status LED indicates the DMX status. When DMX is present, the LED
turns on for 10 seconds, and then it turns off.
Note:
A change to the DMX start address, the local intensity, or
the presence of DMX will “wake” the status LED.
When the local intensity is set to Off, the status LED will flash when there
is a loss of DMX.
With the local intensity set to any other position, the status LED will flash
for 10 seconds when there is a loss of DMX. Then the LED will turn off.