Turning on the lamp
Note that the table above indicates that to turn on the lamp channel number 7 of your DMX 512 controller should be set to between
(241 and 255), to turn it off, channel 4 must have a value between 11 and 30.
You may force the lamp to turn on automatically on startup using the display panel, as described in section
”11.2 Display panel
functions”
in the text describing the
“Func”, lamp ON”
function.
c h a n n e l
f u n c t i o n
type of control
e f f e c t
d e c i m a l
p e r c e n t a g e
1
d i m m e r
step
closed
0-7
0-2.75
proportional
from close to open
8-255
3.14-100
2
c y a n
step
white clear
0-7
0-2.75
proportional
proportional cyan control from white to cyan
8-255
3.14-100
3
m a g e n t a
step
white clear
0-7
0-2.75
proportional
proportional magenta control from white to magenta
8-255
3.14-100
4
Y e l l o w
step
white clear
0-7
0-2.75
proportional
proportional yellow control from white to yellow
8-255
3.14-100
5
A u t o f u n c t i o n
step
No effects
0-9
0-3.53
step
Auto program 1 (all colors, slow color fade)
10-33
3.9-13
step
Auto program 2 (saturated colors, slow color fade)
34-56
13.3-22
step
Auto program 3 (pastel colors, slow color fade)
57-79
22.3-31
step
Auto program 4 (light colors, slow color fade)
80-102
31.3-40
step
Auto program 5 (all colors, medium speed color fade)
1 0 3 - 1 2 5
40.3-49
step
Auto program 6 (saturated colors, medium speed color fade)
1 2 6 - 1 4 8
49.3-58
step
Auto program 7 (pastel colors,medium speed color fade)
1 4 9 - 1 7 1
58.3-67
step
Auto program 8 (light colors, medium speed color fade)
1 7 2 - 1 9 4
67.3-76
step
Auto program 9 (mixed color sequence, color fade at different speed
1 9 5 - 2 1 7
76.3-85
step
Random program
2 1 8 - 2 4 0
85.3-94
step
All programs
241-255
94.3-100
6
L a m p o n / o f f / r e s e t
step
lamp off
0-10
0-3.92
step
Park (no function)
11-30
4.3-11.7
step
cmy and dimmer reset (only once)
31-45
12-17.6
step
cmy reset (only once)
46-60
18-23.5
step
Program stop
61-80
23.9-31.3
proportional
Selected auto-program pause time control (1 sec/8 min)
8 1-241
31.7-94.5
step
lamp on
2 4 2 - 2 5 5
9 5 - 1 0 0
Date: 05/2002
Release: 1
Display panel can inhibit lamp off function
note 1: Channel 6 has a delay time of 6 second to prevent accidental activation.
note 2 :on/off lamp mode is not affected unless an opposite value is received