Error Codes
25
CTO
This message displays after the reset of the fixture if any of the following conditions exist:
•
the fixture head's magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the CTO wheel is not located in the default position after the reset
Focus
This message displays after the reset of the fixture if any of the following conditions exist:
•
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Focus wheel is not located in the default position after the reset
Frost
This message displays after the reset of the fixture if any of the following conditions exist:
•
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Frost wheel is not located in the default position after the reset
Gobo 1
This message displays after the reset of the fixture if any of the following conditions exist:
•
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
Gobo Wheel 1 is not located in the default position after the reset
Gobo 2
This message displays after the reset of the fixture if any of the following conditions exist:
•
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
Gobo Wheel 2 is not located in the default position after the reset
Gobo Rot 1
This message displays after the reset of the fixture if any of the following conditions exist:
•
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
Gobo Rotating Wheel 1 is not located in the default position after the reset
Pan movement
This message displays after the reset of the fixture if any of the following conditions exist:
•
the yoke’s magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Pan movement is not located in the default position after the reset