Colour frame holder

The colour frame holder is equipped with a spring-loaded retaining clip that prevents colour frames 

and accessories from falling out. See 

Figure 2

.

Step 1:

Release the retaining clip by pushing it sideways while gently pulling backwards.

Step 2:

Insert the colour frame.

Step 3:

Lock the retaining clip by pushing sideways while gently pushing forward.

For maximum gel life with specific lens tubes, refer to the tables below. 

W A R N I N G :

Make sure all colour frame accessories are locked in position with the 

retaining clip before hanging the Source Four luminaire.

N o t e :

The performance of saturated colours may be less than desirable in any theatrical 

lighting luminaire, especially when equipped with a 750w lamp. For best results, 

always use high-quality colour media rated for high-temperature use.
ETC’s optional Conical Gel Extender, part # 7060A1048, will provide maximum 

colour media life. For 14° lens tubes, use part # PSF1029. Gel Extenders are not 

recommended for 70° and 90° lens tubes due to the extremely wide-angle beam.
A variety of heat shield products is also available from many colour media 

manufacturers. Follow the manufacturer’s instructions for the use of these 

products.

Lens Tube

Soft Focus Back

(Lamp “flat”)

Sharp Focus

(Lamp “cosine”)

Soft Focus Forward

(Lamp “peak”)

Soft Focus Forward 

(Lamp “cosine”)

14°

worse

good

best

good

70°

best

good

worse

good

90°

best

good

good

worse

19°

worse

better

better

not applicable

26°

worse

better

better

not applicable

36°

better

better

worse

not applicable

50°

worse

better

better

not applicable

ED Lens Tube

Soft Focus Back

(Lamp “flat”

Sharp Focus

(Lamp “cosine”)

Soft Focus Forward

(Lamp “peak”)

Soft Focus Forward 

(Lamp “cosine”)

19°

worse

better

better

not applicable

26°

better

better

worse

not applicable

36°

better

better

worse

not applicable

50°

better

better

worse

not applicable

Figure 2

Retaining clip in the 

locked position

Summary of Contents for ETC 405

Page 1: ...ectronic Theatre Controls Inc All Rights reserved Product information and specifications subject to change Part Number 7060M1210 06 01 Rev A Released August 2007 CE User Manual Production Dates Septem...

Page 2: ...other countries All other trademarks both marked and not marked are the property of their respective owners Declaration of conformity 1 Source Four CE guidelines 2 Basic luminaire 3 Luminaire informa...

Page 3: ...s and tests EN60598 2 17 1990 Specification for luminaires for stage lighting television film and photographic studios outside and indoor equiv BS 4533 102 17 1990 following the provisions of EU LV Di...

Page 4: ...is damaged it shall be replaced by ETC or our service agents Always hang the Source Four CE with the colour frame held securely behind the retaining clip Always replace the lamp if it becomes damaged...

Page 5: ...olour frame retaining clip in the locked position Lamp socket assembly Primary suspension yoke mounting holes Figure 1 Colour frame Gel retainer clip Reflector housing Barrel rotation knob Beam focus...

Page 6: ...ed CAUTION Do not use lamps other than the HPL in Source Four fixtures Use of lamps other than HPL will void your warranty Lamp code Watts Volts Initial Lumen Colour temp Average rated life HPL 750 23...

Page 7: ...l Conical Gel Extender part 7060A1048 will provide maximum colour media life For 14 lens tubes use part PSF1029 Gel Extenders are not recommended for 70 and 90 lens tubes due to the extremely wide ang...

Page 8: ...tightening the knurled bolt Note Verify that the HPL lamp you intend to install is suitable for your facility s voltage 115 120 230 and 240 volt HPL lamps are available See HPL lamp table page 4 Oper...

Page 9: ...mp is centered within the reflector Step 4 Once the lamp is centered turn the outer knob clockwise to lock it in place Step 5 Finally turn the inner knob either clockwise or counterclockwise to achiev...

Page 10: ...t It accommodates either a drop in iris or a motorized gobo device When the slot is not in use a small sheet metal cover secured with two Phillips screws prevents light leakage see Figure 8 Step 1 Use...

Page 11: ...ed position Step 3 Once the barrel is positioned tighten the barrel s rotation knob to lock it in place Adjusting the yoke position The Source Four CE provides multi positioning capabilities within it...

Page 12: ...e barrel with the color frame retaining clip on top Reinstall the beam focus knob retainer bolt and collar Cleaning 5 and 10 polymer lenses To quickly clean the lenses remove dust with a blast of oil...

Page 13: ...the dust from the reflector with a blast of oil free air You may also wipe the reflector with a clean lint free cloth If either method is not sufficient follow these steps Step 1 To protect the lamp...

Page 14: ...vice The PAT device connects to a power source and then attaches to the product via an electrical outlet and test probes The PAT provides a simple pass or fail result allowing rapid testing of large i...

Page 15: ...13 English...

Page 16: ...06 32 656 990 Holzkirchen DE Ohmstrasse 3 83607 Holzkirchen Germany Tel 49 80 24 47 00 0 Fax 49 80 24 47 00 3 00 Hong Kong Rm 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Ba...