Manual Control
239
Levels can be set via the level wheel, from the keypad, and the encoders. The other intensities
will default to 100%.
Control of the individual intensities of a multiple intensity channel is handled using the
parameter buttons in the CIA (see
Manual Control of Non-intensity Parameters (NPs) (on
) or the encoders (see
). Levels assigned to the
individual intensities will act independent of each other and the master intensity.
•
[1][0][0] {Intens 3} [At] [5][0] - sets intensity 3 of channel 100 to 50% intensity.
•
[1][0][0] [At] [7][5] - sets the master intensity of channel 100 to 75% intensity. All
intensities for channel 100 will be mastered to 75% unless they have a separate intensity
set.
In Table view, Eos will default to showing all intensity parameters associated with the
channels.
In summary view, the master intensity is shown. If one of the multiple intensities has a value,
an ‘+’ will display beside the master intensity.
Multicell Fixtures
Fixtures that have multiple same-type parameters can have a multicell profile assigned to
them, as designated by MC in the fixture editor. See
Patching Multicell Fixtures (on page 165)
for more information.
Multicell fixtures have a master channel with a whole number for a channel number and the
appropriate number of additional cells, which will have point numbers for their channel
numbers.
To control the whole fixture ( cells), select the channel number.
To control individual cells, use [.] to put {Cell} on the command line.
To control just the master, use [Shift] & [.] to put {Minus Cells} on the command line. You can
also use the syntax [1] [.] [0] or [1] {Cell} [0] to only control the master.
To select the master and any or all of the cells, you can use the following syntax examples: [n]
[.] [0] [Thru] [n], [n] [.] [0] [+] [n], or [n] [.] [0] [Thru] [n] [-] [n]. The {Cell} softkey can be used
instead of the [.] hardkey.
Example:
Channel 1 is a multicell fixture with four cells.
•
[1] [At] [Full] [Enter]
Sets the intensity of the master channel to full. Note that the intensity
parameter for cells defaults to full.
•
[1] [.] [1] [At] [5] [0] [Enter]
Sets only cell one at 50% of the intensity of the master. Cells are a percentage
of the master level. [.] puts cell on the command line.
This can be especially useful when applying effects or palettes.
Summary of Contents for Element Classic
Page 1: ...Ion Classic User Manual Version 3 1 1 4310M1210 3 1 1 RevA 2022 03...
Page 92: ...78 Ion Classic User Manual...
Page 212: ...198 Ion Classic User Manual...
Page 274: ...260 Ion Classic User Manual...
Page 275: ...Mark 261 Chapter 9 Mark About Mark 262 AutoMark 262 Referenced Marks 263...
Page 308: ...294 Ion Classic User Manual...
Page 346: ...332 Ion Classic User Manual...
Page 364: ...350 Ion Classic User Manual...
Page 378: ...364 Ion Classic User Manual...
Page 384: ...370 Ion Classic User Manual...
Page 426: ...412 Ion Classic User Manual...
Page 438: ...424 Ion Classic User Manual...
Page 444: ...430 Ion Classic User Manual...
Page 450: ...436 Ion Classic User Manual...
Page 458: ...444 Ion Classic User Manual...
Page 479: ...Magic Sheets 465...
Page 480: ...466 Ion Classic User Manual...
Page 530: ...516 Ion Classic User Manual...
Page 558: ...544 Ion Classic User Manual...
Page 578: ...564 Ion Classic User Manual...