Patch
165
Click the {Attributes} softkey to set detailed automated fixture attributes. The following
buttons may be available on this page depending on the device selected: {Preheat},
{Proportion}, {Curve}, {Fan Curve}, {LD Flags}, {GM Exempt}, {Invert Pan}, {Invert Tilt}, {Swap
P/T}, {Color Path}, {Scrollers}, {Gobo Wheels}, {Color Wheels}, and {Effect Wheels}.
Additional buttons maybe available based off of your fixture type. See
.
If your automated fixture includes parameters such as a color scroller or gobo wheel and you
have custom gels or non-standard patterns installed, use the Scroller/ Wheel Picker and Editor
to modify the device patched. The more specific your patch data (including accurate colors and
patterns), the more detailed programming and operating will be. See
Picker and Editor (on page 167)
.
Patching Multicell Fixtures
Fixtures that have multiple same-type parameters can have a multicell profile assigned to
them. The process for patching multicell fixtures is similar to patching automated fixtures.
There are a few differences that are important to understand though.
Note:
It is recommended that when patching multicell fixtures that you work in
patch by channel mode. See
Patching By Channel (on page 158)
.
After you have entered the channel number, click {Type}. You will then select a device type
from the fixture library.
Fixtures that have multicell functionality will be listed with a MC in their mode description in
the device list, and in the {Show} list.
Note:
When using {Search}, the number of cells for a multicell fixture will also be
displayed.
When these devices are patched, they will patch a master channel with a whole number for a
channel number and the appropriate number of additional cells, which will have point
numbers for their channel numbers.
•
[1][0] [At] [5] [Enter] - patches channel 10 and all of its cells starting at address 5.
•
[1][0] [.] [1][2] [Thru] [1] [At] [5] [Enter] - patches channel 10's cells 12 through 1
starting with cell 12's address beginning with address 5.
Note:
If the master channel has only a virtual intensity over the cells, an address will
not be displayed, as that is a virtual parameter.
In the
, you can view and edit the personality for your multicell fixture. For
creating a new multicell fixture, see
Creating Multicell Fixtures (on page 195)
.
On the left of the fixture editor, you can see the fixture name, overall DMX footprint and
number of cells. Click on the caret to see the DMX footprint for the master and the cells. The
cells will be grouped with their profile(s).
Summary of Contents for Element Classic
Page 1: ...Ion Classic User Manual Version 3 1 1 4310M1210 3 1 1 RevA 2022 03...
Page 92: ...78 Ion Classic User Manual...
Page 212: ...198 Ion Classic User Manual...
Page 274: ...260 Ion Classic User Manual...
Page 275: ...Mark 261 Chapter 9 Mark About Mark 262 AutoMark 262 Referenced Marks 263...
Page 308: ...294 Ion Classic User Manual...
Page 346: ...332 Ion Classic User Manual...
Page 364: ...350 Ion Classic User Manual...
Page 378: ...364 Ion Classic User Manual...
Page 384: ...370 Ion Classic User Manual...
Page 426: ...412 Ion Classic User Manual...
Page 438: ...424 Ion Classic User Manual...
Page 444: ...430 Ion Classic User Manual...
Page 450: ...436 Ion Classic User Manual...
Page 458: ...444 Ion Classic User Manual...
Page 479: ...Magic Sheets 465...
Page 480: ...466 Ion Classic User Manual...
Page 530: ...516 Ion Classic User Manual...
Page 558: ...544 Ion Classic User Manual...
Page 578: ...564 Ion Classic User Manual...