2
Installation
1. The screw-less face plate has a snap on design.
Remove the face plate by pressing down with
thumbs on a corner of the raised area and fingers
on the back center of the unit. The KSS-UW can
be mounted with wall anchors and #6 screws
(not supplied). Determine where the station is
to be located then hold the switch station to the
surface of the drywall, (make sure no studs are
behind and ensure the station is level and plumb).
Mark the locations for the wall anchors using the
screw holes as a template, then install the wall
anchors. Screw the KSS to the wall anchors.
Alternate mounting: The KSS can be mounted to a mud ring or with a separate
order item (Barrier kit), it can also be installed on wall outlets. (See Accessories
section or data sheet for ordering information). Follow the Barrier kit
(8188K100X-5) installation instructions.
2. Snap on both the top and bottom snaps of the faceplate (position the slot on the
cover plate on the bottom of the switch station).
3. Test the operation of the station. A slight audible click is expected, and the green
LED will blink on each card insertion to indicate the message was transmitted
and the last measured battery voltage is good. The LED blink is visible through
the keycard plastic
(ambient light may need to be dimmed to view)
.
i
Note:
When a card is inserted and a single Red LED blinks, it is
an indication that the message was transmitted but the
battery voltage is low (less than 2.2V).
When the Red LED blinks 3 times on a card insertion the
message was not transmitted and the battery is critically
low (less than 2.0 V) Replace the batteries immediately.
Lin
king a Station to an Echoflex Controller
The linking process requires the controller or receiver to be mounted, powered and
within range of the station to be linked. Each receiver can support up to 20-30 switch
stations and/or sensors, depending on receiver model.
1. Activate the LEARN button on the controller
2. Insert and extract a card three times in quick succession.
3. Deactivate LEARN mode at the receiver (LEARN mode will time out after 30 s).
4.
Test operation of the station by inserting and extracting the card several times.
There is an egress timer on the card extraction, wait 40 seconds before re-
inserting the card.
Replacing the Battery
The keycard station must be removed from the wall to access the battery. The battery cover
3.28”
[83 mm]
LEDs
visible
through
key card
plastic
Green
Red
Yellow
Do NOT remove this key card