DRd Rack Enclosure Installation Manual
Mounting a DRd Rack Enclosure on a Pedestal
Step 3:
Remove the eight screws and washers that secure the front panel to the unit.
Step 4:
Position the floor stand on floor hardware previously placed for marking the
holes.
Step 5:
Secure the pedestal base to the floor.
Step 6:
Create conduit access in the bottom of the DRd rack. Notice the label inside the
bottom of the rack indicating the recommended locations for conduit access. Do
not create conduit access outside of the recommended locations.
Step 7:
Position the DRd rack on the floor stand pedestal and align with the mounting
holes provided.
Step 8:
Bolt the rack into place.
Step 9:
Reinstall the front panel to the pedestal unit, replacing all hardware removed in
step 3.
The Unison DRd rack pedestal is designed with the same footprint as the Unison
dimmer rack. The acceptable conduit access in the bottom of the DRd rack overlaps the
floor stand access panel for contractor wiring and installation convenience. It is
recommended to secure a DRd rack installed on a pedestal to a wall for greater stability.
432mm
17”
186.7mm
7.35”
35.5mm
1.4”
35.5mm
1.4”
Step 1:
Use the measured
dimensions in the
graphic (right) to mark
the hole locations for the
floor mounting hardware.
Step 2:
Drill holes for floor
mounting hardware.