ETAS
5 Instruments
To change the data representation of a signal
1. In the signal list, select the signals for which you want to change
the data representation.
2. In the toolbar, click
.
3. Select one of the following entries from the
Data Representation
drop-down menu:
Physical Values
Hexadecimal (memory) Values
Decimal (RAW) Values
All selected signal values including cursor and axis values are
shown in the selected data representation. The unit information
is adapted accordingly. If the signal has been on a common axis
before, it is moved to an individual axis with the respective data
representation.
For any kind of signals having float data type, a dialog appears.
Select one of the following bits for the data representation:
8 bit
16 bit
32 bit
Do not cast
In this case, the shown hexadecimal or binary representation
is for the Float value according to the IEEE-754 standard.
To remove a signal from the oscilloscope
1. In the signal list, select one or more signals.
2. In the context menu, select
Remove Signal(s)
.
5.2.9
Creating a Bound in a Strip
1. Define a new calculated signal.
2. Enter a value in the
Formula Definition
field.
3. Define in the section
Output Options
a fixed rate with any value,
for performance reasons preferably slow (e. g. 10 sec).
4. Drag and drop the calculated signal on the same axis as the sig-
nal for which the bound shall be used.
5.3
Scatter Plot
In the scatter plot, one signal is displayed on the X-axis and another signal is
displayed on the Y-axis. If you assign multiple signals to the Y-axis, each signal
is displayed in its individual strip.
The toolbar provides you with the following functions: