ETAS
Technical Data
ES583.1 - User's Guide
26
Supported software interfaces
ETAS provides the Software Development Kit "ECU Bus Interfaces and Integra
-
tion - Package" (EBI-IP). Using this SDK, customers can develop drivers for the
hardware access to integrate the ES583.1 module in their own application soft
-
ware.
6.3
Electrical data
6.3.1
Voltage supply
6.3.2
FlexRay interface (FLX1 and FLX2)
Designation and mapping of FlexRay channels
FlexRay Controller
Physical layer
Other
NOTE
Operating the ES583.1 with older software versions is not possible.
Operating voltage
4.5 V to 5.5 V DC
Supply via the USB port (see chapter
Current consumption, typ. (operation) 300 mA at 5.0 V DC
FLX1
FlexRay channel A
FLX2
FlexRay channel B
Communication controller
Bosch E-Ray
Number of nodes/channels
1 node with 2 channels
FlexRay specification
FlexRay protocol V2.1 Rev. A
FlexRay conformance test
In accordance with ISO 9646
Payload
max. 254 bytes
Hardware-based filtering
Slot counter, Cycle counter and chan
-
nel
Transceiver
Philips TJA 1080A
Termination
100 ohm
Transmission speed, max.
10 Mbaud / channel
Boot time
< 1 s
Timestamp
1 µs 64 bit