Technical Data
ES583.1 - User's Guide
25
The ES583.1 module may be operated only directly on the PC or on an active
hub whose USB port meets the requirements listed in the table.
The module must be directly connected to the USB port of your PC. The use of
USB-cables extending the connection between the ES583.1 and the PC is not
allowed.
Operation of the module at USB 1.0 interfaces is not supported.
Prerequisite for successful initialization of the module
Windows user rights
Ensure that you have the required Windows user rights for installing the USB
driver (administrator rights).
Additional requirements
The PC must also meet the minimum requirements of the application program
used (e.g. INCA). For the minimum requirements for INCA, please see the cor
-
responding software documentation.
General notes
The INCA application software supports up to four ES583.1 modules at the
same time.
6.2.2
Software
Supported applications and software prerequisites
For the configuration of the ES583.1 as well as the control and data acquisition,
you need software in the following versions (or higher):
General
• HSP V10.4.1
• ES583.1 USB driver
NOTE
A specific USB driver must be installed on the PC for operating the ES583.1
module (see chapter 4.2 on page 16).
Inter
-
face
Application /
Protocol
Classifi
-
cation
1)
Support in the
application software
FlexRay XCP on FlexRay
MC
1)
INCA V7.1.4 SP4
3), 4)
FlexRay Monitoring
MC
1)
INCA V7.1.4 SP4
3), 4)
UDS on FlexRay
D
2)
INCA V7.1.4 SP4
3), 4)
1)
: MC: Measurement and Calibration
2)
: Diagnostic
3)
: additionally INCA-ES5xx Add-On V7.1.4 and higher
4)
: additionally INCA-FlexRay Add-On V7.1.4 and higher