![ETAS ES1392.1 User Manual Download Page 25](http://html1.mh-extra.com/html/etas/es1392-1/es1392-1_user-manual_2431163025.webp)
Accessories
25
4
Accessories
4.1
Cables
To connect the ES1392.1 High Current Switch Board to the Power Supply and
to the Controller Board two cables are required, which are described below.
4.1.1
Cable CBAV300.1-2: Connection between ES1392.1 and Power Supply
(Battery Voltages)
Product Data
Short description
CBAV300.1-2
Long description
Cable ITT CA06COM - Ring Tongue (3fc - 2xM8)
Product part number
F 00K 103 223
Specification
Length
2 m
Type
2 wires, 6 mm
2
Connectors
To ES1392.1
ITT Cannon CA06COM-E16-10SB
To power supply
2 ring tongue (RT1+RT2):
DIN 46237, insulated, M8
Function
ES1392.1 ITT Connector
Ring Tongue Connector
+UBatt
A, C
brown
-UBatt
B
blue