Error Output ("ERROR" Connection)
An optocoupler, an LED or a programmable logic controller (PLC) can be con
-
nected directly to the "ERROR" error output for signaling an error state .
4.3.6
"AOUT" Connection ("AOUT" Analog Output)
4.3.6.1
CBS100.1-2: Properties and ratings
State
"ERROR" output
Error
approx. 4 V to ground,
Short-circuit current approx. 10 mA,
internal resistance approx. 400 ohm
No error
High impedance / high-resistance
TIP
The "ERROR" error output is at the potential of the supply voltage and not at
the potential of the output signal.
TIP
When supplying the CBS10x.1-2 Smart Lambda Sensor Cables with AC volt
-
age, the connections "CONFIG" and "ERROR" are without function.
Output voltage
0 V to 10 V
Output current
-5 mA to +5 mA
Output impedance
typ. 10 ohm
Protection
against short circuit, max. external
voltage 0 V to +12 V
Electrical isolation
max. 60 V DC (output to supply volt
-
age)
TIP
The output is high-impedance in de-energized state.