![ETAS CBN101.1 User Manual Download Page 21](http://html1.mh-extra.com/html/etas/cbn101-1/cbn101-1_user-manual_2431232021.webp)
CBN101.1/CBN103.1/CBN105.1/CBN107.1 - User’s Guide
21
ETAS
Technical data
3.3
Electrical data
ETAS guarantees that the measuring accuracy of the CBN101.1/ CBN103.1/
CBN105.1/ CBN107.1 Isolating Measurement Probe
is maintained for one year.
Unless specified otherwise, all data apply at 25 °C.
Property
Description
Number of channels
1
Measuring range
±10 V
Input voltage (max.)
±840 V
(below 4,000 m AMSL)
±600 V
(between 4,000 m and 5,000 m AMSL)
Insulation test voltage
±1,500 V DC
(input against output)
Insulation voltage
±840 V DC
(input against Ubatt-)
Transient overvoltage
2,500 V
Transient resistance
±800 V/μs
Input impedance
12 M
Input capacitance
4 pF
(with straight cable with a length of
20 cm at 10 kHz)
Coupling capacitance
10 pF
(input against output)
Max. measurement error
±(1 mV + |U
in
| * 0.05%)
(at +25 °C)
±(5 mV + |U
in
| * 0.2%)
(at -40 °C to +75 °C)
Note
Note
WARNING!
Dependency of the maximum permissible input voltage of the
CBN101.1/ CBN103.1/ CBN105.1/ CBN107.1 Isolating Measure-
ment Probe on the application altitude!
The maximum permissible input voltage of the CBN101.1/ CBN103.1/
CBN105.1/ CBN107.1 Isolating Measurement Probe depends on its
application altitude above MSL!
Summary of Contents for CBN101.1
Page 1: ...CBN101 1 CBN103 1 CBN105 1 CBN107 1 Isolating Measurement Probe User s Guide...
Page 18: ...CBN101 1 CBN103 1 CBN105 1 CBN107 1 User s Guide 18 Hardware description ETAS...
Page 26: ...CBN101 1 CBN103 1 CBN105 1 CBN107 1 User s Guide 26 Technical data ETAS...
Page 30: ...CBN101 1 CBN103 1 CBN105 1 CBN107 1 User s Guide 30 ETAS Contact Addresses ETAS...
Page 32: ...CBN101 1 CBN103 1 CBN105 1 CBN107 1 User s Guide 32 Figures ETAS...