27
GB
/ 44
–
Neglecting the replacement of the micro filters may lead to failure of the vacuum cleaner!
Storing the accessory
One of the attachments (e.g.
cushion, slit nozzle and brush
) may be slid onto the holder
that is fixed to the telescopic tube. The remaining accessory, floor nozzle, suction tubes and
hose may be disassembled or left assembled and hung into the parking openings
A14
on
the back panel or bottom of the vacuum cleaner. Always store the floor nozzle in the carpet
setting (with the brush inside) to avoid bending of the bristle.
V. MAINTENANCE
Store the vacuum cleaner at a dry place, far enough from heat sources (e.g.
fireplace, stove,
heating element
) and protect it against weather conditions (e.g.
rain, sunshine
). Treat the
appliance surface with a soft damp cloth, do not use coarse and aggressive detergents! For
failure-free operation of the vacuum cleaner we recommend checking the aggregate and the
general condition of the vacuum cleaner in a specialized service centre after 300 hours of
operation, but not later than in 3 years. Store the appliance properly cleaned at a dry, dust
free place out of reach of children and incapacitated people.
Floor nozzle
It is recommended to check the brushes or collectors for possible impurities. If there are some
impurities, remove them.
TURBO nozzle
(pic.24)
If hair or threads are twisted around the mounting of the drive shaft and if they cannot be
removed in the way described above, the impurities have to be removed by dismantling
the nozzles. In the lower part remove the cover. Now you can clean the nozzle using a
suitable tool (eg tweezers). Insert the lid to the nozzle in the opposite direction (you will
hear a snapping sound).
VI. TROUBLESHOOTING
Problem
Cause
Solution
Motor won‘t start
Power supply not connected
The
button is not
switched on
Check the cord, plug and the socket
Press the switch button
The lid cannot be
closed - safety lock
activated
Wrongly inserted dust
container
Dust filter not inserted
properly
Check/repair fixture of the dust container
Check/repair fastening of the carton front
The dust container
or filter can not be
removed
The hose is not disconnected
Disconnect the suction hose of the vacuum
cleaner
Suction power is
insufficient
Regulation is at MIN
Open sucking
Full dust container
Dust bag is full
Clogged micro filters
Nozzle, sucking hose or Hose
is clogged.
Set the regulator to MAX
Close the opening on the hose holder
Empty the container
Replace the dust bag
Replace or clean the micro filters
Remove the blocking objects
The cable cannot be
wound in the entire
length
Twisted cable
Straighten the cable Take out about 50 cm
of the cable and push again the button
Summary of Contents for x472
Page 2: ...2 1...
Page 3: ...3 4 5 7 6 8 1 2 3 G5...
Page 4: ...4 15 17 18 16 19 13 12 14 20 11 9 10...
Page 5: ...5 22 21 23...
Page 45: ......
Page 46: ......