Cleaning (customer)
Cleaning and maintenance
To clean the top pipe, the heat exchanger cover
can also be removed from the boiler. Then the
pipe from the boiler can be cleaned out with the ash
vacuum.
Re-attach the maintenance cover to the piping.
Fig. 2-8: Maintenance cover
Clean the flue tube from the precipitator to the
chimney
Sweep the flue tube from the precipitator to the
chimney and remove flue ash from the chimney using
a vacuum cleaner.
Fig. 2-9: Flue tube
Brush the ash into the chimney and not the pre-
cipitator.
Clean out the internal flue gas ducts
Remove the covers from the rear of the precipitator.
Fig. 2-10: Covers
Remove the insulation over the maintenance covers.
Then remove the maintenance cover with the seals.
Fig. 2-11: Maintenance cover